The counterweight should ideally be fitted at least 20 cm above the float.
3.
After having fitted the float, make sure that the cable is protected and made safe along its entire
length.
4.
Pass the cable through the lower hole of the system (the hole where all the pipes and power
cables pass, pos. 16 fig. 01).
5.
Connect the wires to the RX Vdc terminals and the earth, if available, to the Pe terminal, see fig.
05.
6.
Clamp the cable to the internal pipes of the equipment.
7.
The float switch must change the contact at least 15 cm before the foot valve (pump suction
valve) takes in air.
The level indicator indicates that the tank is completely empty with the lower led on, with all led on
the tank could be from partially to completely full.
4.6.2 Electronic transducer version (Aquaprof Top model):
1.
Position the transducer as indicated in figure 06.
Figure 04
Float switch
Bottom of the tank
Figure 05
37
ENGLISH
Suction pipe