Correspondence between the length and height of the suction pipe
Proceed as follows:
1.
Connect the suction pipe to the connector as indicated in figure 01 point 9, do not over tighten,
the connector has an OR that guarantees the seal.
WARNING
Use table 1 to calculate the maximum length of the suction pipe
4.5 Delivery pipe connection
Proceed as follows:
1.
Connect the delivery pipe to the 1" connector as indicated in figure 01 point 11, insert the
supplied seal to ensure tightness.
2.
Fix the pipe to the wall with a suitable pipe clamp.
The side outlet can also be used, proceed as follows:
1.
Remove the plug on the connector.
2.
Make a 32/35 mm diameter hole in the side of the system's wall.
3.
Remove the flexible pipe from the vertical position and after having sealed it, screw it in the
horizontal position.
4.
Place the plug into the hole where the flexible pipe was fitted.
WARNING
Ideally an on-off valve should be fitted before the float valve so that the mains water can be turned off
in the event of breakage or malfunction, and so that maintenance can be performed in total safety.
4.6 Level sensor installation
4.6.1 Electromechanical float version (Aquaprof Basic model):
1.
Position the float as indicated in figure 04.
Table 1