1.
subject of the supply
2.
general description of the system
3.
technical specifications
4.
installation
5.
start-up
6.
control panel
7.
maintenance
8.
trouble shooting
1. Subject of the supply
The supply includes:
AQUAPROF unit for the management of rain and non rain water.
Fixing bracket.
D10 rawlplugs.
4 Vibration dampers.
Water level sensor with 20 meters of cable:
A) ON/OFF version for Aquaprof Basic models.
B) Electronic transducer version for Aquaprof Top models.
Use and maintenance instructions.
!
Warning: read the present manual before the assembly and operation of the system. For safety
reasons, persons that have not read the instructions should not use the system. Children under the
age of 16 must not use the system and must be kept at a safe distance from the connected
system.
!
Important safety measures – read carefully
The user is responsible for all that concerns the use of the system (electrical, hydraulic systems etc...)
in accordance with the local safety and installation regulations in force. A qualified electrician must
ensure that the required safety measures are present before the system is started. The installation of a
I∆n=30mA circuit breaker on the electrical system is compulsory prior to its use. Check that the
voltage of the mains power supply corresponds to the power supply required by the system. The
indications specified on the rating plate must correspond to those of the electrical system. Do not lift or
move the system with the power supply cable. Check that the power supply cable and plug are intact.
Avoid that the power supply plug and the system itself are subjected to flooding or direct jets of water.
In the event of faults, repair must be carried out by authorised workshops only and only original spare
parts must be used.
We wish to emphasise that we shall not be held responsible for damage caused by:
a) unsuitable repair carried out by unauthorised technicians
b) replacement with non original spare parts
these indications are also valid for the accessories
2. General description of the system
The AQUAPROF unit is used for the management and distribution of rain water. The unit detects the
lack of water in both rain water and mains collection system and corrects it to guarantee that the
system operates correctly (or rather, it never lets the identified users run out of water). Notify in the
event of faults and indicate the type of problem incurred.