Herunterladen Inhalt Inhalt Diese Seite drucken

Defects - Malfunctions - Faema E71 E Gebrauch Und Installation

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 113

22. Defects - Malfunctions

Direct action by the customer
Before calling service personnel, to avoid unnecessary expense, check whether the machine problem corresponds to
one of the cases listed below.
pRoBlEM
The coffee machine does not
work and the display is blank.
Leaking from the filter holder rim
(15).
Coffee dispensing time too short. Coffee ground too coarse .
Coffee drips out of machine.
Loss of water under the machine. Discharge well clogged up.
Machine heated up, but it does
not dispense coffee.
The automatic level-control
devices remain in operation.
MESSaGE
poSSIBlE CaUSES: when the message is
visualized
Machine cold
This message will appear on the display if any
please wait
dispensing key is pressed every time the machine
is turned on until the service boiler pressure falls
below the pre-set working pressure.
Service
This message is displayed when the machine
needed
requires the
In order to eliminate temporary the message, press
the icon
and press the icon
message:
The message will reappears in the successive
relighting of the machine with the main switch.
CaUSE
No electricity supply.
Underpan gasket dirty with coffee.
Coffee too old.
Filter holes blocked or filter holder
(15) outlet hole dirty.
Coffee ground too fine.
Discharge basin hole blocked.
Water supply or water softener tap
closed.
No water in system.
Same causes as above.
Messages in explicit mode
periodic maintenance intervention.
to access the programming menu:
CaRRY oUT
MaInTEnanCE
to cancel out the
SolUTIon
Check the electricity supply.
Check the position of the main switch (1).
Clean using the special brush provided.
Use a finer grind.
Use new coffee.
Clean.
Use a coarser grind.
Clean.
Clean.
Open the taps.
Wait until water is available or call a plumber.
Same solution as above.
VERIFICaTIonS
When the service boiler reaches the pre-set
pressure, the message automatically disappears.
Contact the authorized technical department. The
message will be displayed until the service will be
carried out.
Note: the need to carry out maintenance is
recorded by the machine.
33 EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis