Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 54
I
TEMPORARY SYSTEM SHUTDOWN
("STANDBY")
This function lets you suspend operation of all system devices for
a period of 60 minutes (this value cannot be changed) so that
you can perform routine maintenance without having to discon-
nect the power supply.
CAUTION
If you need to access the electrical parts, parts
that are normally powered, or the rotating parts
of the pumps, you must disconnect the electric
power by turning off the all-pole circuit breaker.
To activate the function, press and hold the "Light"
about 8 seconds: the display will show the message "Sby" followed
by the number of minutes the function will remain blocked.
This function will end after 60 minutes or by pressing and
holding the "Light"
key for about 5 seconds.
NOTES
- If a filtering cycles is active, it will restart 40 minutes after
the end of the stand-by condition at the same point it was
stopped. This means that if 1 hour remained when the cycle
was stopped, when it restarts it will operate for this amount of
time and then stop.
- If the heater was on when stopped, it is turned off immedi-
ately and water is circulated for 30 seconds in order to cool
the heating element.
I
ABNORMAL OPERATING CONDITIONS
ALARM SIGNALS
Alarms are indicated on the display, with the corresponding error
code. You will continue to see the code if the alarm condition persists.
Display Messages
- possible solution
"FLC" The flow switch detects water flow when there is
none (the heater is not turned on).
This may happen if the flow switch, which is connected in series
to the heater, is blocked by deposits or impurities that keep it
from operating properly. The flow switch may also be faulty.
- Contact an authorized Jacuzzi
"FLO" The probe does not detect the water flow (the heater
cannot be turned on).
The cartridge filter and/or pump may be clogged, or the flow
switch may have been installed in the wrong direction with
respect to the normal flow of water. If so, the internal contact will
not close. This will keep the heater from turning on.
The alarm may also appear if the flow switch is faulty.
- Contact an authorized Jacuzzi
"HOH" The measured temperature at the heater is 48 °C
(118 °F) or higher (the heater is turned off).
®
service centre.
®
service centre.
DO NOT ENTER THE WATER
This alarm, which is displayed alternating with the time and
temperature, will disappear as soon as the value drops below
44 °C (111 °F).
- If the alarm condition persists, try turning the switch up the line
from the spa off and back on. If the signal stays on, contact an
authorized Jacuzzi
"Ho" Excessive water temperature.
DO NOT ENTER THE WATER
The water temperature has reached or exceeded 44 °C (111 °F).
It is not possible to activate any function.
- If present, remove cover from spa.
key for
- If the excessive temperature increase is due to sunlight, add cold
water to the spa.
When the temperature has dropped to below 43 °C (109 °F), the
spa should re-activate automatically. If it does not, disconnect the
power supply and contact an authorized Jacuzzi
"rPF" Defective temperature probe.
DO NOT ENTER THE WATER
It is not possible to activate any function.
- Check that the temperature probe is working, or replace it.
"HPF" Activation of safety thermostat.
It is not possible to activate the electric heater.
The electric heater has been deactivated due to overheating. This
may be due to irregular water flow.
- Try turning the switch up the line from the spa off and back on
(system reset). If the signal stays on, contact an authorized Jacuzzi
service centre.
PART TWO

INSTALLATION and MAINTENANCE

CAUTION
The operations described in part two must on-
ly be performed by qualified specialist per-
sonnel.
COMPONENTS and CONNECTIONS
The main components of the spa are (
1 Side panels
2 Pump
3 Electrical control box
4 Electric heater
5 Thermal cover
CAUTION
The thermal cover is not designed to support
weights. Do not sit, walk or lie on the cover. Do
not place objects on it.
31
service centre.
®
i
®
service centre.
®
2 and 3):