Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Instructions - Jacuzzi J-460 Montageanweisung, Bedienung Und Wartung

Vorschau ausblenden Andere Handbücher für J-460:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 86

Operating instructions

Setting water temperature
The LCD display on the control panel displays the temperature
of the spa water.
I
Press either the ( + ) or ( - ) button once to display the set
temperature. If you want the water to heat to a different tem-
perature, simply press ( + ) or ( - ) within 5 seconds: the set tem-
perature advances or decreases by one degree each time one
of these keys is pressed.
I
The heater will turn off when the temperature corresponding
to the thermostat setting is achieved.
Important Heater Details:
- The maximum temperature for which the spa can be set is 40
°C and the minimum is 27 °C.
- If the spa is powered according to the configuration for min-
imum electrical current input (see the pre-installation infor-
mation sheet) turn off the pumps to activate the heater.
- Setting the thermostat at maximum will not accelerate the
heating process. This will only result in a higher ultimate
temperature.
- The heater operates until the water reaches the programmed
"set temperature", then turns off.
The heater will reactivate after the water cools to 1° below
the set temperature.
Display
I
Pressing this key inverts the main display to allow easy read-
ing from either inside or outside the spa.
Activate Pump 1
I
The key "JETS 1" controls the pump 1.
Pressing this key cycles pump 1 on and off.
Activate Pump 2
I Pressing this key cycles pump 2 on and off.
I
Auto Turn Off
Anytime a pump has been manually turned on, it will auto-
matically turn off after approximately 20 minutes.
Selecting desired massage action
Each model incorporates a massage selector that allows you
to customize the massage and performance by diverting water
between various jet systems.
I S
imply turn massage selector to position A (Combo), B, or C
to divert water pressure to various jet groups.
N.B.: The valve is designed to operate in positions A (Combo),
B, and C for optimum performance. For optimum filtration ben-
efits, leave the valve in position A when spa is covered. Select
position B or C for maximum jet performance during spa use.
Adjusting Individual Jet Flow
The water flow to the individual jets in your spa can be increased
or decreased by rotating the outside jet face.
Many jets are also equipped with a direction adjustment mod-
ule, so that you can aim the jet in the desired position.
N.B.: always keep at least 6 of these jets open so as to ensure
efficient water filtering.
Adjusting PowerPro Jets
I
Tilt PowerPro MX2 Jet nozzle to angle of choice as desired.
Rotate nozzle clockwise to reduce flow volume from jet or rotate
counter-clockwise to increase it.
N.B.: Always keep at least 6 adjustable jets open at all times.
Adjusting RX Jets
I
Turn the centre knob clockwise to reduce and/or close the flow
of the jet. Turn it counter-clockwise to open and/or increase the
flow of water.
N.B.: Always keep at least 6 adjustable jets open at all times.
Waterfall Feature
I
Turn waterfall control valve counterclockwise to increase
waterfall output. Turn control valve clockwise to decrease or turn
off waterfalls.
43

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

J-465J-470J-480

Inhaltsverzeichnis