Abnormal operating conditions

- alarm signals -
Alarms are indicated on the display, with the corresponding error code.
You will continue to see the code if the alarm condition persists.
u Signals on display
- possible solution
u "LL"
the level sensor (where present) identifies a low water level. The
term "LL" will appear on the display.
- Refill the water level.
u "HI" Excessive water temperature
DO NOT ENTER THE WATER
The water temperature has reached or exceeded 44 °C . It is not pos-
sible to activate any function.
- If present, remove cover from spa.
- If the excessive temperature increase is due to sunlight, add
cold water to the spa.
When the temperature has dropped to below 43 °C, the spa should
re-activate automatically. If it does not, disconnect the power sup-
ply and contact an authorized Jacuzzi ® service centre.
u "Fr" Water temperature is too low.
The tub water temperature has fallen below 9 °C. However, all func-
tions remain active.
- Activate the heater.
When the temperature exceeds 10 °C, the error message disappears.
u "rPF" Defective temperature probe
DO NOT ENTER THE WATER
It is not possible to activate any function.
- Check that the temperature probe is working, or replace it.

WARNINGS

Make sure that all users know how to use the spa safely.
How frequently you should check water quality depends on
how frequently the spa is used.
Ensure that the chemicals used are suitable for use in spas;
chemicals designed for swimming pools must not be used
as treatment of water in swimming pools and spas is very
different.
CAUTION
Only the load-bearing covers are designed to support
weights (max. 200kg), but they must not be subjected to
violent, sudden stresses (jumping, etc.).
Do not sit, walk, or lie on other types of covers (non-load
bearing). Do not deposit objects.
To prevent accidental falls into the spa, it is advisable to in-
stall the key-locking system provided with the thermal cover
(
4).
CAUTION
Read and follow all the instructions related to the use and
storage methods for chemical products, keeping strictly
to the manufacturers instructions on the packets.
After adding the chemicals, the filtering system should be
run for at least 30 minutes to ensure complete dilution in the
water.
Never clean the filter when the pump is running. Turn off the
main switch first.
Never start the pump and heater if the water level is not
above the highest whirlpool nozzles:
Always turn off the main switch when the spa is empty.
With the TEST button, periodically check the efficiency of
the circuit breaker installed up the line from the spa.
It is a good rule to empty the spa regularly (about every 4-8 weeks),
in order to ensure a change of water and proceed with tub cleaning.
If you are away for any length of time, it is advisable to empty
the spa, as long periods without carrying out water treatment can
damage the spa.
CAUTION
Before emptying, make sure that the chemical additive
values in the water are within the permitted limits.
If in doubt, contact the local authorities.
DO NOT EMPTY THE WATER INTO A SEPTIC TANK.