Wlan-box für 3d-12cam achsmessgerät
Vorschau ausblenden Andere Handbücher für FWA 4650:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

en
46 | FWA 4650 | Mechanical and electrical installation
1
5
4
Fig. 7:
WLAN-Box cable gland
1 Grommet for 3D measurement system LAN cable 1
2 Grommet for 3D measurement system LAN cable 2
3 Grommet for CCD reference system cable
4 Gland for cable assembly to right sensor
5 Gland for cable assembly to left sensor
i
Cable assemblies (2 x) to sensors:
Cable assembly left sensor
2 x LAN cable
3D measurement system
1 x cable
CCD reference system
Tab. 12:
WLAN-Box cable assemblies
5. Route the cable assembly through the cable hole in
the WLAN-Box.
6. Route the cable assembly through the seal.
7. Route the cable assembly through the lock nut.
8. Pull the cable assembly 340 mm into the WLAN-Box.
9. Open up the grommet.
|
1 690 706 220
2014-01-31
2
3
Cable assembly right sensor
2 x LAN cable
3D measurement system
1 x cable
CCD reference system
16900021_Re
Fig. 8:
WLAN-Box cable penetration
1 3D measurement system LAN cable 1
2 3D measurement system LAN cable 2
3 CCD reference system cable
4 Length of cable assembly pulled in = 340 mm
5 Cable gland components
10. In front of the cable hole on the outside of the
WLAN-Box housing, place the cable assembly in
3 cable penetrations of the grommet.
11. Fit a plug in the 4th penetration.
12. Close the grommet.
13. Insert the grommet in the housing half with U-clip.
14. Insert the grommet in the other half of the housing.
15. Fit and clip together the two halves of the housing.
16. Guide the thread of the cable gland into the
WLAN-Box cable hole.
17. Fit the seal in position.
18. Fit the cable gland with the lock nut.
19. Proceed in the same manner for the 2nd cable
assembly.
16900022_Re
1
Fig. 9:
Looped cable assembly in WLAN-Box
1 Example of routing of 3D measurement system LAN cables (4 x)
and CCD reference system cables (2 x)
20. Loop the cable assemblies in the WLAN-Box.
2
1
3
4
5
Robert Bosch GmbH