Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Characteristics; Installation; Hydraulic Connections - DAB E.SWIM Installations- Und Wartungsanleitungen

Vorschau ausblenden Andere Handbücher für E.SWIM:
Inhaltsverzeichnis

Werbung

1- User panel cover
2- User panel
3- QR code
4- Quick guide
5- Terminal board cover
6- External connector
7‐ Power cable inlet 

1.2 Technical characteristics

The technical characteristics are summed up in the table below.
Topic
ELECTRIC POWER
SUPPLY
CONSTRUCTION
CHARACTERISTICS
HYDRAULIC
PERFORMANCE
WORKING
CONDITIONS

2 INSTALLATION

The system must be used preferably in the technical area for installing swimming pool pumps.
In no case must it be run if exposed without protection to atmospheric agents.
The place of installation must be well ventilated.

2.1 Hydraulic connections

Follow these recommendations with care:
Install the pump horizontally, on a flat and sturdy base, as close as possible to the edge of the pool.
The pump is able to overcome a maximum difference in level of 4 m (with non-return valve).
Install the filter and the pump in a protected, well ventilated place.
Avoid letting the motor be immersed in water.
For pump-system connections use only adhesives suitable for plastics.
Parameter
Voltage
Frequency
Maximum current
Maximum power
Overall dimensions
Empty weight (excluding packaging)
Protection class
Motor insulation class
Maximum head
Maximum flow rate
Maximum working pressure
Max liquid temperature
Max ambient temperature
Table 1 – Technical Characteristics
ENGLISH
Figure 2
574 x 310 x 316 mm / 22.6 x 12.2 x 12.4 in
37
E-SWIM
220-240 V +/- 10%
50/60 Hz
5.6 SFA
1250 W
18 kg / 39 lb
IP55
F
16 m / 52 ft
32 m3/h / 141 gpm
2,5 bar
40°C / 104°F
50°C / 122°F

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis