H
Installation situation
Roof hooks (3)
I
J
Profile rail (7)
26
Hole for fixing
the profile rail (1)
Fitting with
roof hooks (3)
Fitting with
roof hooks (3)
Hole for fixing
the profile rail (1)
cm
Locking bracket (9)
Roof hooks (3)
Collector strip (1)
The collector strip (1) is subsequently
I
fitted to the roof hooks (3) (set of bolts,
washers and screws M 10 from the BP kit
221336).
First secure the collector strip (1)
I
through the second hole to the first lower
roof hook. The upper roof hook is secured
with a suitable slot to the collector strip.
The first and last holes in the collector strip
are provided for securing the profile rails
(7).
The upper profile rail (7) is fitted to
I
J
both collector strips (1) through the upper
hole.
For this, ensure that the profile rail is
O
supported on the wide side of the collector
strip.
The lower profile rail is fitted to both
collector strips through the lower hole.
Where several rooftop frames are used,
connect these to each other with frame
connection sets.
Have an expert carry out lightning
protection measures.
The collectors are positioned and connected
as described.
Then retighten all screws.