Single stage rotary vane pumps

Werbung

Only the recommended lubricants, or lubricating oils with similar
characteristics and known and experimented quality, should be used.
Oil changes must be made with the oil at a sufficiently high
temperature, after leaving the pump to cool for a few minutes
following operation.
The drain and filler plugs must not be left open any longer than is
strictly necessary. When performing maintenance, look out for all
signals that may precede a breakdown, in particular:
Maintenance technicians must:
Use original spare parts wherever possible and repair a broken part
as best as possible on site or send it back to the manufacturer for
repairs. For all problems arising, or to order spare parts, refer to our
service department.
Agilent Technologies Italia S.p.A.
Vacuum Products Division
Via F.lli Varian 54
10040 Leini, (Torino) – Italy
Tel.: +39 011 997 9111 Fax: +39 011 997 9350
Toll-Free: 00 800 234 234 00
Here following the correct procedures for MS40+ Oil Change and
Filter Cartridge Replacement are described.
MS40+ Single Stage Rotary Vane Pumps User Manual / 87-901-008-01
traces of corrosion;
oil leaks;
slack joints or couplings.
be aware of all applicable national directives concerning accident
prevention during work on motor-driven pumps and should
know how to apply them;
have read and understood all the sections on "Safety Rules";
be familiar with the essential design features and operation of the
pump;
know how to use and consult the pump documentation;
be concerned about proper operation of the pump;
make a note of any irregularities in operation of the pump and
take the necessary action, where appropriate.