; This key determines the bus type of the installed boards. All installed
boards
; must be of the same bus type. This key can only be set in the section of
the first board.
BusTyp
; The default mode is "HostControlledBuffered". If there is no ComMode entry
; in the PROCONOS.INI file the default settings are applied. If ComMode =
; "NoChangeOfMode" the actual CIF card mode is applied. In this case the
; mode can be changed e.g. by application of the SyCon tool.
; "DirectDeviceControlled"
; "BufferedDeviceControlled"
; "UncontrolledDirect"
; "HostControlledBuffered"
; "HostControlledDirect"
; "NoChangeOfMode"
;
needs to be set for every board
ComMode
; The Startup DPM configuration.
ConfigurationFile="/ata0/OS/DP/DPMconf0.dbm"
; The COM module firmware path - location of the firmware file terminated
with "/"!
FirmwareFileFolder="/ata0/OS/DP/"
More then one board using:
If more than one board are placed in the respective hardware, or more than
one board are assigned in the
ProConOS-IO-Groups, an assignment for the hardware board and ProConOS-IO-
Group-Board is necessary.
[CIF_KW_V2.0@0]
driver: @0 ... @3.
;1 = CIF hardware driver assigns board number, only possible in section of
card 0
ManualBoardAssign = 1
; The device number of the card can be found on the card used. Also it is
possible to read out this with the SyCon.
DeviceNr
= 10504000
; The series number of the card can be found on the card used. Also it is
possible to read out this with the SyCon.
SerNr
[CIF_KW_V2.0@1]
driver: @0 ... @3.
; The device number of the card can be found on the card used. Also it is
possible to read out this with the SyCon.
DeviceNr
= 10304100
; The series number of the card can be found on the card used. Also it is
possible to read out this with the SyCon.
SerNr
104
= "USR"
; The proper Bus type for XCx controller.
Direct Data Transfer, DEVICE Controlled
Buffered Data Transfer, DEVICE Controlled
Uncontrolled Direct Data Transfer
HOST Controlled, Buffered Data Transfer
HOST Controlled, Direct Data Transfer
Keep the mode set by Sycon,
= "HostControlledDirect"
; possible are up to four instances of the same
= 00003930
; possible are up to four instances of the same
= 00005648
Wichtig!
Das Lesen der Einträge aus den Sections [IODriver] und
[CIF_KW_V2.0@0] verwendet andere Betriebssystem-Routinen.
Vor dem "=" dürfen keine Leerzeichen stehen, z.B.:
nicht
ManualBoardAssign = 1
sondern
ManualBoardAssign=1