Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Trouble-shooting list

Before calling customer service, please restart the device. If the fault occurs repeatedly or if the described measures
do not remedy the problem, please contact Truma Service.
Fault
Cause
F 3
Undervoltage < 10.5 V.
F 4
Overvoltage > 15.0 V.
F 10
Gas cylinder or quick-acting valve in gas line
closed.
Gas pressure regulation system iced up.
Proportion of butane in cylinder too high.
F 13
Fault after long stop period or cartridge change.
F 16
No gas.
F 20
Undervoltage < 10.5 V.
F 27
Soiled (non-deionised) water in system.
F 36
Overvoltage > 15.0 V.
F 40, F 50
Inlet for supply air and exhaust outlet closed.
F 60
No gas. Check gas supply.
Air inlet for supply air and exhaust outlet closed.
F 62
Ambient temperature too low.
F 63, F 64
Ambient temperature too high.
F 65, F 66, F 67,
Air inlet for supply air and exhaust outlet closed.
F 68
F 106
Battery temperature too high.
F 107
Inlet for supply air and exhaust outlet closed.
F 110
Soiled (non-deionised) water in system.
F 111
Maximum run-time until service is required has
been reached.
S 1
Device starting too frequently. Defective / worn
out battery.
S 2
Undervoltage < 10,5 V.
S 3
Window above exhaust outlet open
(window switch).
S 4
No gas. Check gas supply.
S 5
Vehicle engine running. D+ (D-) signal active.
S 6
Water container (internal) empty.
S 8
Device temperature too low.
Drain valve
Temperature at drain valve less than approx. 3 °C.
(FrostControl) is
(If the temperature is below approximately 3 °C,
opening.
the drain valve will open automatically!)
The drain valve
Temperature at drain valve is below approxi-
(FrostControl) can
mately 7 °C.
no longer be
closed.
Rotary switch is not at "Operation".
28
Rectification
Check battery voltage and charge battery if
necessary.
Short-term immediate measure. Switch off
powerful consumers and start vehicle engine
until the device is running.
Insufficient battery capacity, replace worn out
battery if necessary.
Error in standby – check on-board power
system.
Error in charging mode – please contact Truma
Service.
Check gas supply and open valves.
Use regulator heating (EisEx).
Use propane. (Butane is unsuitable, particularly
at temperatures of less than 10 °C).
Several starting procedures may be necessary.
Check gas supply. See error F 10.
See error F 3.
Flush system 2-3 times.
(Drain water from system via the drain valve
and fill with deionised water via the top-up
container).
See error F 4.
Check whether openings are clear. Remove soil-
ing (slush, ice, leaves etc.).
See error F 10.
See error F 40.
Heat room in which equipment is installed.
Restart device at a lower ambient temperature.
See error F 40.
Restart device at a lower ambient temperature.
See error F 40.
See error F 27.
Device needs servicing. Please contact Truma
Service.
Insufficient battery voltage / battery capacity,
replace battery if necessary.
See error F 3.
Close window.
Start device
See error F 10.
Device switches to standby.
Add deionised water via the top-up container.
See error F 62.
Switch on vehicle heater if necessary. When
temperature is above approx. 7 °C at drain valve,
it can be closed again
Switch on vehicle heater if necessary. When
temperature is above approx. 7 °C at drain valve,
it can be closed again
Turn the drain valve's rotary switch to "Operation",
then press the push button until it engages.

Quicklinks ausblenden:

Werbung

loading