Herunterladen Diese Seite drucken

Fuses; Disposal; Technical Data; Dimensions - Truma VeGA Gebrauchsanweisung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fuses

Always replace fuses with an identical fuse.
F1 – F4 3.15 A – medium time-lag – 5 x 20 mm
F5
0.25 A – medium time-lag – 5 x 20 mm

Disposal

The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.

Technical data

(determined in accordance with EN 62282-3-1 or Truma test
conditions)
Type of gas
Liquid gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Internal water capacity
3.5 litres
Gas consumption
Warm-up phase 330 g/h
Charging phase 100 g/h
System warm-up time
20 – 25 min. at Ta = 20 °C
Input power at 12 V DC
max. 50 W (warm-up phase)
Output power at 12 V DC
max. 250 W
Charging current
max. 23.8 A (with charging voltage of 10.5 V)
Charging voltage
10.5 V – 15 V
Undervoltage limit
10.5 V
Ambient temperature (operating)
+ 3 °C to + 45 °C
Supply air temperature (operating)
-20 °C to + 40 °C
Maximum incline (operating)
8 %

Dimensions

717 X 462 X 290 mm (L X W X H)
Weight (without water contents)
40 kg
The right to effect technical modifications is reserved!
F 1
F 2
F 3
F 4
F 5
Dimensions
717
All dimensions in mm.

Accessories

Window switch (part no. 34000-85800)
Other accessories (without illustration):
External cable kit (part no. B30010-37000)
Gas filter (part no. 50600-01)
Air outlet channel (part no. 40040-32500)
VeGA service pack (part no. B30010-36000)
27

Quicklinks ausblenden:

Werbung

loading