Continued
Defrost
: 0=none, 1= EL, 2= Gas, 3 = Brine
Defrost method
Defrost stop temperature
Interval between defrost starts
Max. defrost duration
Displacement of time on cutin of defrost at start-up
Drip off time
Delay for fan start after defrost
Fan start temperature
Fan cutin during defrost
0 =Stop on time, 1=S5, 2=S4, 3=
Defrost sensor:
(Application 1-5 and 7: Both S5A and S6A.
Application 6: individual S5A and S5B)
Pump down delay
Drain delay (used at hot gas defrost only)
(used at hot gas defrost only)
Max. aggregate refrigeration time between two defrosts
Heat in drip tray. Time from defrosting stops to heating in
the drip tray is switched off
Regulation parameter for refrigeration
Period time at PWM
Max. opening degree at PWM
Min. opening degree at PWM
Expert setting. Windup at PWM
Expert setting. Kp at PWM
Expert setting. Tn at PWM
Fan
Fan stop temperature (S5)
Pulse operation on fans: 0=No pulse operation, 1=At
thermostat cuts out only, 2= Only at thermostat cut outs
during night operation
Period time for fan pulsation (on-time + off-time)
On-time in % of period time
Real time clock
Six start times for defrost.
Setting of hours.
0=OFF
Six start times for defrost.
Setting of minutes.
0=OFF
Clock - Setting of hours
Clock - Setting of minute
Clock - Setting of date
Clock - Setting of month
Clock - Setting of year
Miscellaneous
Delay of output signals after start-up
Input signal on DI1. Function:
0=not used. 1=status on DI1. 2=door function with alarm when
open. 3=door alarm when open. 4=defrost start (pulse-signal).
5=ext.main switch. 6=night operation 7=
changeover
(activate r21). 8=alarm function when closed.
9=alarm function when open. 10=case cleaning (pulse signal).
11=forced cooling at hot gas defrost,
12=night cover
Network address
On/Off switch (Service Pin message)
IMPORTANT! o61 must be set prior to o04
(used at LON 485 only)
Access code 1 (all settings)
Used sensor type
: 0=Pt1000, 1=Ptc1000,
0=Pt1000, 1=Ptc1000,
Max hold time after coordinated defrost
Select signal for display view. S4% (100%=S4, 0%=S3)
16
code
d01
d02
d03
d04
d05
d06
d07
d08
d09
d10
d16
d17
d18
d20
n63
n64
n65
n66
n67
n68
F04
F05
F06
F07
t01
- t06
t11
- t16
t07
t08
t45
t46
t47
o01
o02
Thermostat band
o03
o04
o05
o06
o16
o17
Instructions RI8LM352 © Danfoss 10/2007
1
2
3
4
5
6
7
1
1
1
1
1
1
1
0/No
1
1
1
1
1
1
1
0°C
1
1
1
1
1
1
1
0 hrs/Off
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
-50 °C
1
1
1
1
1
1
1
0/no
1
1
1
1
1
1
1
0
1
1
1
1
1
1
1
0 min.
1
0 min.
1
1
1
1
1
1
1
0 hrs
1
0 min.
1
1
1
1
1
1
1
60 sec.
1
1
1
1
1
1
1
0°C
1
1
1
1
1
1
1
0°C
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
60 sec
1
1
1
1
1
1
1
-50°C
1
1
1
1
1
1
1
0
1
1
1
1
1
1
1
1 min.
1
1
1
1
1
1
1
0 %
1
1
1
1
1
1
1
0 hrs
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
0 hrs
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
1 day
1
1
1
1
1
1
1
1 mon.
1
1
1
1
1
1
1
0 year
1
1
1
1
1
1
1
0 sec
1
1
1
1
1
1
1
0
1
1
1
1
1
1
1
0
1
1
1
1
1
1
1
0/Off
1
1
1
1
1
1
1
0
1
1
1
1
1
1
1
0/Pt
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
0 %
Min.
Max.
Fac.
3/bri
1/EL
25°C
6
48 hrs
8
360 min.
45
240 min.
0
60 min.
0
60 min.
0
0 °C
-5
1/yes
1/yes
3
0
60 min.
0
60 min.
0
48 hrs
0/OFF
240 min.
30
1200 sec.
300
100°C
100
100°C
0
10
4
10
4
1800 sec
900
50°C
50
2
0
30 min.
5
100 %
100
23 hrs
0
59 min.
0
23 hrs
0
59 min.
0
31 day
1
12 mon.
1
99 year
0
999 sec
5
12
0
119
0
1/On
0/Off
100
0
1/Ptc
0/Pt
360 min.
20
100 %
100
AK-CC 450
Actual