Menu survey
Parameter
Function
Normal operation
Temperature (setpoint)
Thermostat
Differential
Max. limitation of setpoint setting
Min. limitation of setpoint setting
Adjustment of temperature indication
Temperature unit (°C/°F)
Correction of the signal from S4
Correction of the signal from S3
Manual service, stop regulation, start regulation (-1, 0, 1)
Displacement of reference during night operation
Define thermostat function
1=ON/OFF, 2=Pulse width modulating (PWM)
Definition and weighting, if applicable, of thermostat sensors
- S4% (100%=S4, 0%=S3)
Time between melt periods
Duration of melt periods
Temperature setting for thermostat band 2
r01
S3B
Correction of the signal from
S6
Correction of the signal from
S6B
Correction of the signal from
Definition and weighting, if applicable, of thermostat sensors
when night cover is on. (100%=S4, 0%=S3)
Heat function
Neutral zone between refrigeration and heat function
Time delay at switch between refrigeration and heat
function
Alarms
Delay for temperature alarm
Delay for door alarm
Delay for temperature alarm after defrost
High alarm limit for thermostat 1
Low alarm limit for thermostat 1
High alarm limit for thermostat 2
Low alarm limit for thermostat 2
High alarm limit for sensor S6 at thermostat 1
Low alarm limit for sensor S6 at thermostat 1
High alarm limit for sensor S6 at thermostat 2
Low alarm limit for sensor S6 at thermostat 2
S6 alarm time delay
With setting = 240 the S6 alarm will be omitted
Alarm time delay or signal on the DI1 input
Alarm time delay or signal on the DI2 input
Signal for alarm thermostat. S4% (100%=S4, 0%=S3)
Delay for S6 (product sensor alarm) after defrost
Delay for S3B alarm during normal regulation
Compressor
Min. ON-time
Min. OFF-time
Time delay for cutin of comp.2
AK-CC 450
Code
- - -
r01
r02
r03
r04
r05
r09
r10
r12
r13
r14
r15
r16
r17
. As differential use
r21
r53
r59
r60
r61
r62
r63
A03
A04
A12
A13
A14
A20
A21
A22
A23
A24
A25
A26
A27
A28
A36
A52
A53
c01
c02
c05
Instructions RI8LM352 © Danfoss 10/2007
EL-diagram page 2 or 3
Min.-value
1
2
3
4
5
6
7
1
1
1
1
1
1
1
-50°C
1
1
1
1
1
1
1
0.1 K
1
1
1
1
1
1
1
-49°C
1
1
1
1
1
1
1
-50°C
1
1
1
1
1
1
1
-10
1
1
1
1
1
1
1
0/°C
1
1
1
1
1
1
1
-10 K
1
1
1
1
1
1
1
-10 K
1
1
1
1
1
1
1
-1
1
1
1
1
1
1
1
-25 K
1
1
1
1
1
1
1
1
1
1
1
1
1
0 %
1
1
1
1
1
1
1
0 hrs
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
-50°C
1
1
-10 K
1
1
1
1
1
1
1
-10 K
1
-10 K
1
0 %
1
0 K
1
0 min.
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
-50°C
1
1
1
1
1
1
1
-50°C
1
1
1
1
1
1
1
-50°C
1
1
1
1
1
1
1
-50°C
1
1
1
1
1
1
1
-50°C
1
1
1
1
1
1
1
-50°C
1
1
1
1
1
1
1
-50°C
1
1
1
1
1
1
1
-50°C
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
0 %
1
1
1
1
1
1
1
0 min.
1
0 min.
1
1
1
1
1
1
1
0 min.
1
1
1
1
1
1
1
0 min.
1
0 sec
Factory
Actual
Max.-value
setting
setting
50°C
2
20 K
2
50°C
50
49°C
-50
10
0
1/F
0°C
10 K
0
10 K
0
1
0
25 K
0
2
1
100 %
100
10 hrs
1
10 min.
5
50°C
2
10 K
0
10 K
0
10 K
0
100 %
100
50 K
2
240 min.
0
240 min.
30
240 min.
60
240 min.
90
50°C
5
50°C
-30
50°C
5
50°C
-30
50°C
5
50°C
-30
50°C
5
50°C
-30
240 min.
30
240 min.
30
240 min.
30
100 %
100
240 min.
90
240 min.
30
30 min.
0
30 min.
0
999 sec
5
15