uncoupled, following the manual opening and closing of the door, the drive should be re-coupled. The un-coupling may not be performed while the drive unit is in use
as this may cause permanent damage to the drive unit.
[D000668] Failure to comply may result in severe injuries due to crushing by the door or other hazards.
Caution! Danger.
19. ROUTINE MAINTENANCE INSTRUCTIONS
[A000140] Activities which may be performed by the Owner after careful reading the instruction.
[C000509] Electric power doors: every 3 months:
• check whether the limit switches are properly adjusted (to check this, operate the gate and carefully observe where the gate stops),
• check whether the electrical protective devices operate properly (if applicable) by simulating the operating conditions,
• check the photocells - simulate the conditions,
• check the overload switch - the gate should stop and reverse when the leaf runs into an obstruction,
• check the mechanism for manual uncoupling of the drive unit,
• check whether electrical cables do not show any signs of wear,
• clean the photocell covers and the signal light cover lens on a regular basis,
• replace the transmitter batteries at least every 12 months.
• [B000212] If any operating malfunctions or damage to the components is found, do not operate the product. Immediately stop using the product and
contact an authorised service company or a Professional Installer.
Caution! Danger.
• [C000463] Maintain the electric drive unit according to its Operating Manual.
[A000141] Activities to be performed by a professional installer only
[A000166] Any alterations and modifications to the door should be agreed on with the door manufacturer.
[C000510] Inspect the drive unit at least every year and:
• check whether the photocells operate correctly, depending on the setting, when the beam is crossed, the gate should either not move at all or should not close,
• if the electric drives malfunction, disconnect the drive unit from the power supply for at least 5 seconds and reconnect,
• check the electrical system, in particular, inspect the electrical cables,
• check whether the force threshold complies with the specification provided in Annex A to the PN-EN 12453 standard,
• if after the check you find that the parameters fail to meet the requirements specified in the PN-EN 12453 standard - the dynamic force of the main closing edge
should not exceed 400 [N], the dynamic time should not exceed 750 [ms] - perform automatic calibration in accordance with section 13.6,
• check the mechanical components responsible for safety and proper operation of the product,
• perform maintenance actions prescribed by the product Owner,
• any defects and irregularities in the operation of the product found during inspection should be eliminated immediately, the damaged elements posing a safety haz-
ard to the user should be repaired or replaced,
• all actions should be carried out in accordance with the Installation and Operating Manual of the gate.
[A000107] Actions restricted to authorised service agents of the Manufacturer:
• any modifications of the product;
• repairs of components.
• [C000465] Power cable replacement.
• [C000467] Disconnect the drive power supply during all maintenance and inspection works.
• Also a battery power supply should be disconnected if it has been delivered.
20. WARRANTY CONDITIONS
[A000142] This product is covered by a commercial warranty according to the Manufacturer's General Warranty Terms & Conditions.
[A000079] The manufacturer reserves the right to introduce design modifications due to technological progress that do not alter the prod-
uct functionality, without prior notice.
This documentation is copyright of the manufacturer. Copying, reproduction and usage in full or in a part without the written consent
of the owner is prohibited.
[A000048] This document has been translated from Polish. In case of discrepancies, the Polish version prevails.
Technical documentation and description + IIiO/AWso2018/06/2018/ID-97354
Assembly and Operating Instructions – Drive unit for gates AWso2018
EN
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis