15.4. BASIC CONTROLLER FUNCTIONS
[D000723] Remotes can be programmed using 3 methods:
• quick programming of remote controls - press and hold the "OK" button for 5
seconds, the "Pr" message will be displayed on the screen. Press the button
of the pilot/pilots that you want to program. The quick remote programming
procedure ends automatically 15s after the last transmitter is coded
• remote programming of remote controls - press and hold buttons 1 and 2
of an already programmed remote control for 5 seconds, the "Pr" message
will be displayed on the screen. The procedure is the same as with quick
programming
• manual programming of remote controls - enter the installer code, then navigate
to the "Pr" function in the controller. Next, select a free cell in the controller
memory - when the cell is free, its number flashes. Select a free cell and press
the button on the remote control you are programming
Photocell operation mode settings - enter the installer code, go to the "bA"
function in the controller menu, press "OK" and select the "tP" function. The op-
tical barrier has 4 operating modes. The default mode is 1
Reaction of the drive unit to photocell interruption
Mode
number
When opening
0
No reaction
1
No reaction
2
Stops the gate
3
No reaction
4
Stops the gate
Wicket function – enter the installer code, then go to the "Fr" function in the
controller menu. Next, press the "OK" button and select the percent value of the
opening width to open the gate like a wicket
Automatic closing – enter the installer key and go to the "Au" function in the
controller menu. Next, press the "OK" button and select time, in minutes, after
which the gate closes automatically
Automatic calibration reset – enter the installer code, then go to the "Cr"
function in the controller menu. To reset gate calibration, press "OK" 5 times.
After resetting the calibration, the next operation of the gate will start the cali-
bration process
Restoring factory settings – enter the installer code, then go to the "FA"
function in the controller menu. To restore factory settings, press the "OK" but-
ton 5 times. Restoring factory settings also resets gate calibration
Changing the installer code – enter the installer code, then go to the "Pn"
function in the controller menu. Next, press the "OK" button and enter the in-
staller code twice
Adjusting the slow–down areas – enter the administrator code, then nav-
igate to the "Lo" function in the controller menu. Next, press the "OK" button
and select adjustment of the slow–down area when opening ("to") or adjustment
of the slow–down area when closing ("tc"). Both areas can be adjusted from
–5 (shorter) to 5 (longer). Each "tc" and "to" unit modifies the slow–down area
by about 10 cm. Every time the slow–down area is modified, automatic calibra-
tion must be run – the procedure starts automatically
Housing estate function – allows a transmitter to take over temporary con-
trol (30s) of the controller. For this period of time, the signals of other transmitters
will be ignored. Commands issued by the transmitter that took over control of the
controller will be performed normally.
16. CONTROLLER DISASSEMBLY
[D000724] The drive unit should be disassembled by reversing the sequence
of the installation procedure.
17. OPERATION REMARKS
[D000725] The following basic guidelines will ensure long and smooth oper-
ation of the drive:
• protect the drive unit from agents that could damage varnish and metal, such
as acids, lyes, and salts,
• the drive unit should be opened in accordance with the instruction manual
supplied with the electrical equipment,
• [B000210] Do not modify the adjustments done by the Profes-
sional Installer.
Caution! Danger.
• [A000062] Do not perform any product repairs
on your own.
• [C000461] During the full operating cycle of the door, the user shall
visually monitor the door operating area and keep all bystanders
away until the door is fully opened/closed.
10
Assembly and Operating Instructions – Drive unit for gates AWso2018
When closing
No reaction
Opens the gate
Opens the gate
Stops the gate
Stops the gate
18. OPERATING INSTRUCTION
• [C000383] Do not stay, pass, run or drive under the door when
it is in motion. Before opening or closing,
• ensure that no persons, and especially children or any objects, are
in the path of the moving garage
• door. No persons, objects or vehicles are allowed to stay within
the clearance of the open door.
• [C000384] Do not use the garage door to lift any ob-
jects or people.
• [A000103] Do not use faulty products! Do not use the product
and contact an authorized service centre if the product is malfunc-
tioning or its subassemblies are damaged.
• [A000125] Do not remove, alter or disable any protec-
tive equipment.
• [B000194] The product can only be operated when all the required
safety devices are in place and if these devices are operational.
• [C000042] This equipment can only be operated by children
above 8 years of age, persons with impaired physical/and
or mental performance and inexperienced users under supervi-
sion or according to the operating manual and with the principles
of safe use and related hazards properly explained. Do not allow
children to clean or perform maintenance works on the device.
Mind that children must never play with this equipment.
• [B000211] Keep batteries, rechargeable batteries or other small
power sources out of the reach of children. Hazard of swallowing
by children or pets!
Deadly hazard!
If this emergency occurs, immediately consult a medical doctor
or seek medical attention. Do not shorten the battery leads. Do not
throw the batteries into fire. Do not recharge non-rechargeable bat-
teries. Explosion hazard!
• [C000076] WARNING: Do not obstruct the door leaf
movement area. Make sure that no persons, especially chil-
dren, or objects stand in the way of a closing or opening door leaf.
• [C000077] No barriers may stand in the way of a door leaf.
CAUTION! Danger.
• [C000078] Opening and closing the door with the drive may
be performed only when the door is within the operator's sight.
Door in motion should be watched.
CAUTION! Danger.
• [C000079] The door may be approached only when its motion
(opening or closing) is finished. Approaching the door in motion
is not allowed.
CAUTION! Danger.
• [C000080] Remote control transmitters, transmitters or other con-
trol equipment to activate the door should be kept out of reach
of children, to avoid unauthorised activation. Children should not
be allowed to play with this equipment. Transmitters should be kept
in dry places.
CAUTION! Danger.
• [D000726] Do not uncouple during operation of the drive, risk
of permanent damage to the drive unit.
• [D000727] Do not intentionally block movement of the gate or the
drive unit. Do not insert your fingers and other objects in the strip
and the toothed wheel.
• [D000728] Do not use the drive when it needs repair or adjust-
ment, risk of bodily injury.
• [A000170] It is strictly prohibited tu use a malfunctioning gate,
it is especially prohibited to use the gate if it shows visible damage.
18.1. MANUALLY OPERATED GATE
[D000729] In the case of a power outage and to open the gate remotely, un-
couple the drive unit using the lever. In order to re-couple the drive, push the
lever in the initial position.
[B000104] All the manually operated products should be opened and closed
smoothly, without any jerking which decreases product durability and safety
of use.
18.2. POWER OPERATED GATE
[D000731] Unlocking is not allowed when the drive is operating, as this can
cause permanent damage to the drive.
[D000732] To open and close the gate with a drive unit, press the button on the
remote control transmitter or operate the accessory connected to one of the
control inputs.
[B000154] The drive unit is constantly coupled under normal operating conditions
in the power-operated door (with electric drive). The drive can be uncoupled only
in emergencies, e.g. in the case of drive breakdown. After the drive unit was