15.2. PROGRAMMING THE CONTROLLER
[D000721] The drive unit is programmed using the "OK", "ESC", "+", and "-" buttons located on the drive unit controller and the digital display. To access the control-
ler menu, enter the four-digit installer key. Press "+" or "-" to start entering the key. The factory installer key is 1234.
Function
No.
Level
Range
1
2
1
Pr
1, ..., 99
bA
tP
0, 1, 2, 3, 4
2
AF
oF, 0.1, ..., 9.9
Ft
on/oF
3
cr/Cr
4
Au
oF, 0.1, ..., 9.9
5
UP
1, ..., 20
6
Fr
oF, 1, ..., 40
SE
St
on/oF/rE
SP
0, 1, 2
7
So
Ot/OZ/3F/U
Su
ZA/UZ
bL
CA*
on/oF
8
PP
on/oF
ZP
on/oF
9
LS
nc/no
Er
10
EP
0, ..., 9999
EZ
0, ..., 9999
LC
11
cc
0, ..., 999999
co
0, ..., 999999
12
Pn
0000, ..., 9999
13
FA
14
oS*
on/oF
15
PF
1, ..., 99*
Lo
16
to
5, ..., -5
tc
5, ..., -5
8
Assembly and Operating Instructions – Drive unit for gates AWso2018
Factory
Definition
setting
-
Remote control programming
Optical barrier
1
Operating modes
Closing after interrupting the bar-
oF
rier path
oF
Barrier self-test
Gate calibration information
oF
Automatic closing
-
Overload setting
40
Wicket – partial opening of the gate Width setting determining the width to which the gate opens when the wicket mode is activated
Controller inputs
on
Stop
0
Resistive safety edge input
Ot
Control input 1
UZ
Control input 2
Controller interlocks
oF
Automatic calibration interlock
Simple remote control programming
oF
interlock
Remote programming of remote con-
oF
trols interlock
nc
Limit input type setting
Error counter
-
Overload counter
-
Short-circuit counter
Cycle counter
-
Closing counter
-
Opening counter
1234
Change installer code
Restore factory settings
oF
Housing estate function
Number of programmable
-
transmitters
Slow-down area adjustment
0
Opening
0
Closing
*This function requires the administrator code to be entered
Description
Programming or removing one remote control. Removing all remote controls – the PF function.
Optical barrier settings
Optical barrier operating modes:
0 – Photocells are inactive
1 – No reaction when opening, reverse motion when closing
2 – Stop when opening, reverse motion when opening
3 – No reaction when opening, stop when closing
4 – Stop when opening, stop when closing
Time in minutes after which the gate will start closing when the barrier is interrupted
Starts the photocell self-test before each movement of the gate
Informs whether the gate is calibrated (Cr) or not (cr). 5x OK resets the gate calibration
Time in minutes after which the gate will start closing automatically
Gate operating force adjustment. The parameter is selected automatically during the calibration
Controller input setting
on – stop input active
oF – stop input active – stop when activated
rE – stop input active – reverse when activated
0 – safety edge input inactive
1 – reverse when opening, reverse when closing
2 – no reaction when opening, reverse when closing
Ot – open
OZ – open / close
3F – open / stop / close / stop
U – open partially
ZA – close
UZ – open partially / close
Controller interlock settings
When this function is active, calibration will not be performed
When this function is active, simple remote control programming is disabled
When this function is active, remote programming of remote controls is disabled
Can be used to set the type of limit switches that are used – normally open or normally closed
Records errors
Records all stops caused by the triggering of the overcurrent safety device
Records all motor short-circuits
Records cycles
Records all closing cycles of the gate
Records all opening cycles of the gate
To change the installer code, the new installer code has to be entered twice
To restore the factory settings, press the OK button 5 times.
This function enables one transmitter to take over control of the controller unit for a short period
of time.
Shows the number of transmitters that can be programmed. 5x OK removes all stored transmitters
This function adjusts the slow-down areas
Opening slow-down area adjustment
Closing slow-down area adjustment
IIiO/AWso2018/06/2018/ID-97354 + Technical documentation and description