21. FAQ

• Diode on transmitter (remote control) is off
• Control system does not react to signal from operative transmitter (remote control)
• Control system operates correctly but door does not move
• Drive does not stop upon contact with barrier
• Drive stops immediately after starting
• Door does not stop at open/close position
• Drive opens but does not close, photocells are connected
• In final closing phase – door opens
• In final opening phase – door closes
If you have any doubts or recurring problems, please contact an authorised service outlet.
12
Assembly and Operating Instructions – Drive unit for gates AWso2018
Reason
• Replace batteries, possibly replace the transmitter.
• Check controller feed.
• Program transmitter.
• Check if the toothed wheel is meshed with the toothed bar.
• Check if manual drive may be opened.
• Check overload rate adjustment.
• Check overload rate adjustment.
• Check limit switches function.
• Check photocells connection.
• Check photocells.
• Check limit switches function.
• Check overload rate adjustment.
• Check limit switches function.
• Check overload rate adjustment.