Opening the safety/drain valve

Turn the rotary switch by 180° until it engages, whereby the
push button pops out (position c). The water from the boiler
drains through the drainage socket (d).
The FrostControl drainage socket (d) must be free of contami-
nation (slush, ice, leaves, etc.) at all times so the water can
drain out easily! There shall be no claims under guarantee
for damage caused by frost!

Closing the safety/drain valve

Check whether the rotary switch is set to "On" (position a),
i.e. parallel to the water connection and engaged.
Close the safety/drain valve by pressing the push button. The
push button must engage in position (b) "closed".
Only when the temperature at the safety/drain valve is above
approx. 7 °C can it be closed manually with the push button
(position b) and the boiler filled.
Truma supplies a heating element (part no. 70070-01) as an
accessory, which is plugged into the FrostControl and fixed in
place with a retaining bracket. This heating element heats the
FrostControl to approx. 10 °C when the Combi D is switched
on. This means that the boiler can be filled sooner, irrespective
of the temperature in the installation compartment.

Automatic opening of the safety/drain valve

If the temperature at the drain valve is below about 3 °C, it
will open automatically and the push button pops out (posi-
tion c). The water from the boiler drains through the drainage
socket (d).

Filling the boiler

Check whether the safety/drain valve is closed (see "Closing
the safety/drain valve").
When the temperature at FrostControl is below ap-
prox. 7 °C, first switch on the heater to warm the instal-
lation compartment and FrostControl. The safety/drain valve
can be closed after several minutes, when the temperature at
FrostControl is above 7 °C.
– Switch on the power for the pump assembly (main switch
or pump switch).
– Open hot water taps in kitchen and bathroom, (set prese-
lecting mixing taps or single-lever fittings to "hot"). Leave
the fittings open for as long as it takes for the boiler to
displace the air and fill up, and the water to flow without
interruption.
If only the cold water system is being operated without
the boiler, the boiler still fills with water. To avoid frost
damage, the boiler must be drained via the safety/drain valve,
even if it was not operated.
In the event of frost, filling may be prevented by residual
water that has frozen. The boiler can be thawed out again
by briefly starting it up (max. 2 minutes). Frozen lines can be
thawed out by heating up the interior.
If connected to a central water supply (rural or urban
connection), a pressure reducer must be used, which
will prevent pressures of greater than 2.8 bar from occurring
in the boiler.
12

Draining the boiler

If the motor home / caravan is not used during the
winter, the boiler must be drained!
– Switch off the power to the pump assembly (main switch or
pump switch).
– Open hot water taps in kitchen and bathroom.
In order to check the water that is flowing out, place an
appropriate container (capacity 10 litres) beneath the
drainage socket (d) of the safety/drain valve.
– Open safety/drain valve
(see "Opening the safety/drain valve").
The boiler is now drained directly to the outside via the
safety/drain valve. Check whether all of the water in the boiler
(10 litres) has been drained into the container via the safety/
drain valve.
There shall be no claims under guarantee for damage
caused by frost!

Initial start-up

(or when the fuel tank has run empty)

Filling the fuel lines

The heater normally has to be started up several times to fill
the fuel lines if an automatic filling device is not being used.
Check to make sure the cowl is unobstructed. Remove any
covers that may be present.
Switch off unit at control panel. The unit automatically per-
forms 2 starting attempts (initial and repeat start) per switch-
on procedure with a run time of 2 minutes in each case. If no
flame is detected after the repeat start, the unit switches to
fault and has to be switched off and on again at the control
panel.
After a total of 15 unsuccessful starting attempts (initial
and repeat start) without forming a flame, the equip-
ment is blocked. To remove the block, please contact the
Truma Service Centre (see Truma Service Booklet or
www.truma.com).
Check fuel lines and connections for leaks after filling the fuel
lines.

Start-up

The use of the installed control panels (analogue / digital)
is described in separate operating instructions.
The interior can be heated with or without water, depending
on the setting.
– Check to make sure the cowl is unobstructed. Remove any
covers that may be present.
– Fill boiler with water if necessary (see "Filling the boiler").
– Switch off unit at control panel.

Switching off

– Switch off heater at control panel.
– The switch-off procedure may be delayed by several min-
utes because of internal heater operations.
Always drain water contents if there is a risk of frost!