Herunterladen Diese Seite drucken

Assembly; Features And Controls; Operation - Briggs & Stratton 020622-00 Bedienungsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 38
Automatic Shut-Off
A sensor will shut off the motor when the spray gun trigger
releases or locks. If the motor continues to run while the spray
gun trigger is released or locked, DO NOT USE THE MACHINE.
Contact a Briggs & Stratton authorized service dealer.
NOTICE ON/OFF switch should always be in the OFF
position (0) when pressure washer is not in use.
Motor Overload
An overload protection device automatically shuts off the
motor if it overheats or draws excessive current. If the
device trips, disconnect power by pressing master ON/OFF
switch to OFF (0) position. Let unit cool for 30 minutes and
press ON/OFF switch to ON (I) position.
EU Disposal
This symbol indicates the owner of batteries and
electrical or electronic equipment shall not dispose
of this product with unsorted municipal waste. This
product should be disposed of in environmentally
appropriate waste locations. Please contact Briggs & Stratton
or your local retailer for additional disposal information.

Assembly

Attach Support Tubes and Handle
1. Slide supports (1,A) into slots. Align and attach with
screws (1,B). Maintain alignment while tightening.
2. Place handle (2,A) onto supports and align holes.
3. Insert carriage bolts (2,B) through holes from inside of
unit, attach with plastic knobs (2,C), and tighten.
4. Attach nozzle holder (3,A) with screw (3,B) to back,
left side of handle.

Features and Controls

Spray Gun
A
B
Accessory Tray
C
Detergent Tank
D
Master ON/OFF Switch K
E
Plastic Wand
F
Spray Tips

Operation

Connecting Hose and Water Supply
NOTICE Use ONLY cold water (less than 38°C (100°F)).
1. Pressing red button on gun (5,A), insert high pressure
hose (5,B) into gun (4,A) until it snaps in place.
2. Attach high pressure hose (4,K) to outlet (4,L) and tighten.
3. Confirm water inlet screen and black rubber washer is
installed in water inlet coupling (6,A).
4. Attach water inlet coupling to water inlet (6,B) and tighten.
NOTICE Make sure water source is capable of supplying water
at a flow rate greater than 11.4 LPM (3.0 GPM) and 0.14-0.55
MPa (1.4-5.5 BAR or 20-80 PSI) at end of garden hose.
5. Run water through garden hose to clean out debris.
NOTICE Using a backflow preventer at pump inlet could
cause pump damage. There MUST be at least 3 m. (10 ft.)
of unrestricted garden hose between pressure washer inlet
and backflow preventer.
Figure
1 2 3
Figure
4
G Electric Cord w/ PRCD
H Identification Label
J
Water Supply Inlet
High Pressure Hose
L
High Pressure Outlet
M Turbo Spray Tip
Figure
4 5 6
WARNING! Water that has flowed through a
backflow preventer is considered to be non-potable.
6. Connect garden hose (6,C) (not to exceed 15 m (50 ft.))
to water inlet (4,J) and tighten.
7. Turn ON water, point gun in a safe direction, press trigger lock
button (5,C), then squeeze trigger to purge system of air.
8. Insert wand (4,E) into spray gun (4,A), apply inward pressure,
and twist wand 1/4 turn clockwise until securely in place.
9. Insert spray tip (4,M) into wand (4,E), applying inward
pressure until it SNAPS into place.
Starting Pressure Washer Figure
WARNING! Spray could splash back or propel objects
resulting in serious injury. Always wear indirect vented
(chemical splash) safety goggles marked to comply with
ANSI Z87.1 when using or in vicinity of this equipment.
1. Press master ON/OFF switch (4,D) to OFF (0) position.
WARNING! Risk of electrocution. Use of an extension
cord could cause electric shock or burn resulting in
death or serious injury. DO NOT use an extension cord
with this electric pressure washer. Your home's electrical circuit
receptacle or extension cord may not provide lifesaving portable
residual current device (PRCD) protection.
2. Plug electrical power cord (4,G) into a dedicated
electrical circuit (8) rated for 220-240 volts AC at 10
Amps that is properly insalled in accordance with all local
codes and ordinances. Circuit is not to supply any other
electrical needs.
3. Press RESET button (7,C). Indicator light (7,B) should
be ON.
NOTICE Indicator light must be ON for the electric
pressure washer to operate.
4. Press TEST button (7,A). Indicator light (7,B) should
be OFF.
5. Press RESET button (7,C). Indicator light (7,B) should
be ON.
WARNING! Risk of electrocution. Non-operating PRCD
could result in death or bodily injury. If indicator light does
not stay ON after test and reset, do not use PRCD.
6. Press master ON/OFF switch to ON (I) position.
7. Point gun in a safe direction, press trigger lock button
and squeeze trigger.
The motor will start and stop as spray gun trigger is depressed
and released.
Spray Tips
The turbo spray tip whirls a powerful pin-point jet of water
for intense cleaning. The white spray tip is for general soap
applications, and the yellow spray tip is for various high
pressure applications.
Usage Tips
• For most effective cleaning, keep spray tip from
20 to 61 cm. (8 to 24 in.) away from cleaning surface.
• If you get spray tip too close, especially using a
yellow spray tip, you may damage cleaning surface.
• DO NOT get closer than 15 cm (6 in.) when cleaning tires.
4 7 8
5

Werbung

loading

Diese Anleitung auch für:

020672-00