Troubleshooting

Problem
Pump has following
problems: failure to produce
pressure, erratic pressure,
chattering, loss of pressure,
low water volume.
Unit fails to start when
spray gun trigger is
squeezed.
Detergent fails to mix with
spray.
Hose connections leaking.
For all other issues, see a Briggs & Stratton Authorized Dealer.

Specifications

Allowable Pressure
Max Flow
Rated Pressure and Flow
Max Water Supply Temperature
Rated Voltage
Rated Frequency
Power Consumption
Current
Protection Class
Protection Degree
Hand - Arm Vibration a hd
Uncertainty K
Sound Pressure Level L pA
Uncertainty K pA
Measured Sound Power Level L WA
Guaranteed Sound Power Level L WAd
* Per EN 60335-2-79: 2012.
8
Cause
1. Water inlet is blocked.
2. Inadequate water supply.
3. Garden hose is kinked or leaking.
4. Clogged water inlet screen.
5. Spray tip is obstructed.
1. Water supply is not turned on.
2. Unit is not turned on.
3. Garden hose is too long.
4. Fuse blown or circuit breaker tripped.
1. High pressure spray tip is installed.
1. Garden hose loose to water inlet.
2. Loose high pressure hose connections.
3. Damaged o-ring.
Correction
1. Clear inlet.
2. Provide adequate water flow.
3. Straighten garden hose or replace if leaking.
4. Clean or replace water inlet screen.
5. Clean spray tip.
1. Turn on water supply.
2. Press master ON/OFF switch to ON (I)
position. Reset PRCD.
3. Use only 15.24 m (50 ft.) maximum
garden hose.
4. a.) Replace fuse or reset circuit breaker.
b.) Disconnect other electrical
appliances and turn off lights in the
circuit or operate on dedicated circuit.
c.) Run 5 minutes with turbo spray tip.
1. Install white spray tip.
1. Hand tighten garden hose.
2. Remove hose and reinstall.
3. Replace o-ring.
MPa/BAR/PSI
LPM/GPM
MPa/BAR/PSI @ LPM/GPM 12.0/120/1,740 @ 5.5/1.45
°C/°F
V
Hz
W
A
Class
IP xx
m/s 2
m/s 2
dB(A)
dB(A)
dB(A)
dB(A)
16.0/160/2,320 *
8.0/2.1 *
38/100
220 - 240
50/60
2,500
9.0
Class II
IPX5
≤ 2.5 *
0.2 *
74 *
2 *
94 *
96 *
BRIGGSandSTRATTON.COM