Herunterladen Diese Seite drucken

Maintenance; General Recommendations; Storage - Briggs & Stratton 020622-00 Bedienungsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 38

Maintenance

General Recommendations

Regular electric maintenance will improve performance
and extend the life of the pressure washer. See any
Briggs & Stratton Authorized Service Dealer for service. DO
NOT allow children to clean or maintain without supervision.
The electric pressure washer's warranty does not cover
items that have been subjected to operator abuse or
negligence. To receive full value from warranty, operator
must maintain pressure washer as instructed in this
manual, including proper storage as detailed in Storage.
WARNING! To ensure machine safety, use only original
spare parts from the manufacturer or approved by the
manufacturer. Should you have questions about
replacing components on your pressure washer, please visit our
website at BRIGGSandSTRATTON.COM. If cord is damaged,
see an Briggs & Stratton Authorized Service Dealer.
Spray Tip Maintenance
Clean clogged spray tip to correct excessive pump pressure:
1. Press master ON/OFF switch to OFF (0) position.
Remove power cord plug from electrical outlet.
2. Remove spray tip from end of plastic wand (E).
3. Use a small paper clip to free foreign material clogging
or restricting spray tip.
4. Reinstall spray tip into plastic wand.
O-Ring Maintenance
The use of lubricant (petroleum or synthetic grease) helps
seat o-rings providing an improved seal. Apply lubricant
to o-rings prior to assembling high pressure hose (pump
end) (A), high pressure hose (gun end) (B), garden hose
to the pump (C), and plastic wand (gun end) (D).
Purchase an O-Ring Maintenance Kit by contacting a Briggs
& Stratton Authorized Service Dealer. NEVER repair leaking
connections with sealant of any kind. Replace o-ring or seal.
Figure
4
Figure
9
PRCD Fuse Replacement
WARNING! To reduce the risk of fire, replace
only with 13-amp BS 1362 rated fuse.
If equipped with fuse within PRCD:
1. Locate fuse on pin side of PRCD plug.
2. Using a flat-head screwdriver, remove cover (A) and
fuse. Remove fuse (B) from cover. Replace fuse with
13-amp BS 1362 rated fuse.
3. Insert cover and fuse.

Storage

Follow steps 1-10 in After Each Use.
NOTICE Water left in pump could freeze and permanently
damage pump. Freeze damage is not covered under warranty.
Protecting the Pump
To protect the pump from damage caused by mineral
deposits or freezing, use PumpSaver to prevent freeze
damage, and lubricate pistons and seals.
NOTICE Failure to protect unit from freezing termperatures
will damage pump and render unit inoperable. Freeze
damage is not covered under warranty.
Final Storage Tips
1. Wrap high pressure hose on top hook of accessory tray.
2. Coil power cord on bottom hook of accessory tray.
3. Store spray gun and plastic wand on accessory tray.
Store spray tips in holder.
4. Cover unit with a suitable protective cover that does not
retain moisture and store in a clean, dry area protected
from freezing temperatures.
Figure
10
7