Operational characteristics
4.9.3
Charging with the multiple charging station
Up to eight Dräger X-am 7000 instruments or power packs can be loaded
simultaneously with the multiple charging station.
Check that the local mains voltage agrees with the value shown on
the bottom of the power supply unit. (The input voltage for the
power supply unit can be changed only by DrägerService).
When attaching the charging modules, disconnect the power pack
from the mains supply!
Mounting charging modules
1. Turn the slit of the lock to the horizontal position with a screwdriver
or coin.
2. Insert the projecting tongue of the charging module (simultaneous
power supply) until it engages.
3. Close the lock by turning it by 90 degrees (with the slit vertical).
2
1
Attach additional charging modules in the same way.
Always connect or disconnect the charging modules individually and
not in groups in order to prevent the charging station from becoming
damaged. During transportation, the power pack and the charging
modules should also always be handled individually and without
inserted instruments.
Position the instrument on an even and level surface.
50
2
2
1
1
NOTICE
i
i
The measuring mode can still be used when the instrument is
in the charging module.
Connect the power supply unit
to a mains outlet.
1. The green "Mains" LED lights.
Place the Dräger X-am 7000 in
the charging module with its
front panel pointing to the right.
Charging of a completely
discharged battery takes:
–
NiMH power pack 3.0 Ah –
approx. 4 hours
–
NiMH power pack 6.0 Ah –
approx. 8 hours
A short-circuit of the charging
contacts in the charging modules, e.g. due to metal objects that have
fallen into the modules, should be avoided due to the danger of
overheating and incorrect displays on the charging module.
00223725_1.eps
1
00323725_1.eps
Dräger X-am 7000