Herunterladen Inhalt Inhalt Diese Seite drucken

Exposure Alarm Stev; Exposure Alarm Twa; Battery Pre-Alarm; Battery Main Alarm - Dräger X-am 7000 Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für X-am 7000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operational characteristics
A blocking alarm on the CatEx channel (due to a significant
exceeding of the measuring range) cannot be acknowledged via
the » OK « key. The blocking alarm on the CatEx channel is
acknowledged manually by switching the device off and back on
again in fresh air (free of flammable gases and vapours).
4.7.4

Exposure alarm STEV

The alarm threshold for the short-term value STEV (mean value of
the concentration over the mean-value period) has been exceeded.
The alarm threshold for the short-time exposure value or
the duration of exposure to excess concentrations has been
exceeded.
Intermittent signal tone and blinking red
alarm lamp.
Display: Gas type, measured value,
units and » STEV « displayed alternately
4.7.5

Exposure alarm TWA

The alarm threshold for the total exposure TWA (over an adjustable
shift duration) has been exceeded.
Intermittent signal tone and blinking red
alarm lamp.
Display: Gas type, measured value,
units and » TWA « displayed alternately
In the case of an exposure alarm:
WARNING
!
Leave the area immediately.
After this alarm, the deployment of personnel is subject to
the applicable regulations.
After leaving the area, acknowledge the alarm:
Press the » OK « key: only the signal tone is switched off.
46
4.7.6
Charge the power pack as soon as possible, page 49.
STEV
ppm
STEV
Acknowledge the alarm:
4.7.7
Intermittent signal tone and blinking red
alarm lamp.
In addition, the icon »
TWA
ppm
TWA
right of the display.
Acknowledge the alarm:
Clear the exposure evaluation. See the "X – am–7000 Technical
Manual" for further details.

Battery pre-alarm

Intermittent signal tone and blinking red
alarm lamp.
In addition, the icon »
« blinks on
the right of the display.
or
replace the alkaline batteries, page 52
Press the » OK « key: only the signal tone is switched off.

Battery main alarm

« blinks on the
The instrument will switch itself off automatically after about
2 minutes to protect the battery from exhaustive discharge.
Charge the power pack, page 49.
or
replace the alkaline batteries, page 52
Press the » OK « key: only the signal tone is switched off.
Dräger X-am 7000