Operational characteristics
Calibrate the instrument in fresh air in the following cases:
If the displayed value in pure air differs from 0 or, for O
from 20.9 or for CO
sensor from 0.035 Vol.-%.
2
If a DrägerSensor Smart CatEx or DrägerSensor Smart IR is fitted
and you are prompted to calibrate it in fresh air.
If you install a new sensor in the instrument.
Calibrate the instrument in fresh air, see page 52.
NOTICE
i
i
Do not leave the instrument lying around without the power
pack for long periods of time. The internal back-up battery
may run out as a result and the date display of the internal
database may fail.
For use in category areas M2 (mining):
Operating only with carrying
frame and stomach belt
(order no. 83 17 682).
1)
EN 60079-29-2 – Guide for the selection, installation, use and maintenance of
apparatus for the detection and measurement of combustible gases or oxygen.
EN 45544-4 – Electrical apparatus used for the direct detection and direct
concentration measurement of toxic gases and vapours - Part 4: Guidelines
for selection, installation, use and maintenance.
40
4.3

Activating info mode

sensor
2
The Info-Mode serves to display information about central instrument
settings and status values. Info Mode can be activated while the
instrument is in use or when it is switched off. The number of screens
displayed depends on the status of the instrument.
Press and hold the » ▲ « key (longer than 1 second) – Information
about the instrument is then displayed on several screens.
If the » ▲ « key is held down, the next screen is displayed every
3 seconds.
If the » ▲ « key is not held down, you can step to the next screen
at any time by briefly pressing the key again.
After display of the last screen, the Info Mode is terminated and the
instrument returns to its previous state
You can also terminate the Info Mode at any time by pressing the
» OK « key.
If no key is pressed for 30 seconds, the instrument automatically
returns to its previous state.
Example of info mode:
Screen 1
Details of the instrument status (faults and
notes are explained in clear text), for
example:
This screen is not displayed if Info Mode
is activated with the instrument
switched off.
Screen 2
Instrument
information
settings).
EC-H
S
2
Sensor warming up !
Status report
(configuration,
ARUB0001
SW1.41
1.1.2004
Battery
Datalogger
Pump installed
System info
Dräger X-am 7000
1/4
11:32
14:30
0:45h
2/3