Voltage dif-
ference
Voltage
scale

8. Battery settings

To change the charge / discharge parame-
ters, call up the "Battery settings" sub-
menu.
In this menu you can set all the important
battery parameters such as battery type,
cell count, capacity, etc.
It is absolutely essential to set the follo-
wing values correctly, otherwise you risk
damaging the battery:
Battery type, cell count, Delta-Peak sensiti-
vity (NC / NiMH batteries only), capacity,
charge / discharge current, discharge vol-
tage and cut-off temperature (charge pro-
cess only).
You will find tips on setting these values in
the section entitled "A brief guide to battery
types".
Operating instructions
Power Peak E1
Time difference
Voltage
Reference
points
Temperat
ure curve
Time
Battery type:
NICD - NC batteries
NIMH - Nickel Metall Hydrid batteries
LIPO -
Lithium Polymer batteries (3.7 Volt)
PB -
Lead-Acid batteries (2.30 Volt)
LiFE -
Lithium Ferrum (A123 etc. 3.3 Volt)
LiON - Lithium Ion (3.6 Volt)
A special additional process is also availa-
ble when a BID-chip / key is plugged into the
charger.
SPECIAL Lead-acid or Lithium batteries
which are charged using the CC - CV pro-
cess. Charge voltage freely selectable within
the range 2 ... 6 Volt.
Charge voltage / peak sensitivityJe This
line contains the set-up facility for charge
voltage, according to the battery type you
have selected (Lithium and Lead-acid batte-
ries, also Special battery), or for peak cut-
off sensitivity (NICD and NIMH batteries
only).
Battery type
NICD = Std. 7 mV/cell (available range 3 - 25 mV)
NIMH = Std. 5 mV/cell (available range 3 - 25 mV)
Lead = Fixed value 2.3 V/ cell
LiPO = Fixed value 4,.2 V/ cell
LiON = Fixed value 4.1 V/ cell
LiFE = Fixed value 3.7 V / cell
11