Installation instructions
Safety instructions
In-vehicle installations must comply with
the technical and administrative regula-
tions of the respective country of use (e.g.
EN 1648, VDE 0100-721). In other coun-
tries, the relevant regulations must be ob-
served. National regulations and rules
must be followed.

Scope of delivery

1 Truma CP plus VarioHeat control panel
1 cover (depending on type)
1 screw (fastening control panel upper section)
4 screws for wall mounting (depending on type)
1 set of operating and installation instructions
1 12 V connector cable 30 cm (+ = red, - = red/black)
1 fuse holder with 1 A fuse (depending on type)
1 connector cable TIN bus 6m (depending on type)
To be ordered separately:
CP plus cover
Connector cable (TIN bus) available in different lengths.
Mounting frame DBT

Description

The Truma CP plus VarioHeat
reversal protection) is supplied with power via a 12 V con-
nector cable. The control panel is connected to a
Truma VarioHeat heater, Truma E-Kit, Truma air condition-
ing system
and/or an Truma iNet Box with a connector cable
2
(TIN bus). The independently installed Truma CP plus VarioHeat
control panel is suitable for wall mounting on a level surface.
And/or Truma CP plus VarioHeat CI-BUS for CI-BUS – not retrofittable.
1
In combination with a Saphir compact, a "control panel cable
2
coupling" is essential between the air conditioning system and the
heater. Order the "control panel cable coupling" separately. Not in
conjunction with inverter TG 1000 sinus.
1
control panel (with polarity
39