If the cause has not been remedied, the malfunction will re-
occur and the control panel will jump to the "Warning/Error"
menu level again.
Cause not eliminated / return to the setting level
– Press the Back button.
In this case, the error in the Truma CP plus VarioHeat
control panel is not acknowledged and the warning
symbol (Figure 34 - 1) remains. The appliance remains in fault
status. Other connected appliances can be operated.
Reading out the error fault code
When the error has been acknowledged, the fault code can
be opened again:
– Select the warning symbol (Figure 34 - 1) with the rotary
push button.
– Tap the rotary push button. The current error fault code is
displayed.

Maintenance

The Truma CP plus VarioHeat control panel is maintenance-free.
In order to clean the front panel, use a damp, non-scouring
cloth. If this is not sufficient, use a neutral soap solution.

Disposal

The appliance must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-Life Vehicle Regulation) must be observed.
36

Technical data

Display
Dimensions (L x W x H)
Operating temperature
range
Storage temperature range -25 °C to +70 °C
Interfaces
Truma CP plus VarioHeat
Truma CP plus
VarioHeat CI-BUS
Power supply
Power consumption at
rated voltage 12 V 
Quiescent current
consumption
Weight
Protection class
Protection type
Subject to technical changes.
LCD, monochrome, with
background lighting
92 x 103 x 40 mm
-25 °C to +60 °C
TIN bus
TIN bus, CI BUS
8 V – 16.5 V 
max. 65 mA (100% back-
ground lighting)
6.5 mA – 10 mA (stand-by)
max. 3 mA (Off)
approx. 100 g
Class III
IP00

Quicklinks ausblenden: