Safety instructions

Residual gas: No smoking, no naked flames!
– If the DuoControl gas pressure regulator is installed downstream
of other pressure regulating equipment, the supply pressure range
must correspond to the regulated pressure range of the upstream
pressure regulating equipment, with allowance being made for the
pressure loss in the gas pipe between the two sets of equipment.
– In the case of caravans and motor homes with 30 mbar consumers,
the maximum pressure loss ΔP of the downstream installation to
the consumer must not exceed 5 mbar (ΔP5).
– To ensure proper operation, the gas pressure regulator must be fit-
ted vertically to a stable wall/roof of the gas cylinder box and must
be securely screwed in place with 2 screws arranged diagonally. The
outlet connection must always face downwards (Figures 1a, 1b).
Attention must be paid to the installation position.

Protection against dirt / oil

A gas filter must be installed upstream of the gas pressure regulator
to provide reliable protection against dirt / oiling. A set of operating
and installation instructions is supplied with the gas filter.