Verfügbare Sprachen

4
Fig. 20

Set time

Display, 24 h mode
4
Fig. 21
– With the rotary push button (8), select the "Set time" sym-
bol in the menu bar (4).
The hour display flashes.
– Set the hours with rotary push button (8).
– The minutes display flashes when the rotary push button (8)
is tapped again.
– Set the minutes with rotary push button (8).
– Tap the rotary push button (8) to confirm the value.
Display, 12 h mode
4
= a. m.
= p. m.
Fig. 22

Service menu

1. Calibrating the room temperature sensor of the
heater (OFFSET)
The room temperature sensor of the heater can be individually
adjusted to the sensor's installation situation. The setting can be
made in increments of 0.5 °C within the range of 5 °C to -5 °C.
Example:
Set room temperature 23 °C;
OFFSET = -1 °C;
– Setpoint value for heater = 22 °C
Fig. 23
Presetting: 0 °C (Celsius).
2. AC SET
1,2
The sensed room temperature can – during operation of the
automatic climate control – be perceived differently during
cooling than during heating. "AC SET" is used to set an offset
between cooling and heating. The setting can be made in in-
crements of 0.5 °C within the range of 0 °C to +5 °C.
Example:
Set room temperature 23 °C;
AC SET = 2 °C
– Setpoint value for air conditioning
system = 25 °C
Fig. 24
Presetting: +1 °C (Celsius).
Only available if the air conditioning system and heater are
1
connected.
Only available if ACC is set to "ON".
2
31