Table 7: Further Control Sequences, supported by IBM Emulation Mode
(Native Commands)
Escape Sequence
ESC [
ESC
ESC * P1 P2 P3 v1 . . . vn
Parameter Table Graphic Density:
P1
Graphic type
0/0 Standard Density (K)
0/1 Double Density (L)
0/2 2xDensity / 2xSpeed (Y)
0/3 Quadruple Density (Z)
0/4 CRT I
0/5 Plotter
0/6 CRT II
0/B Double Density Plotter
2/0 Standard Density
2/1 Double Density
2/6 CRT III
2/7 Triple Density
2/8 Hex Density
*) consecutive horizontal dots cannot be printed.
Example: box 8x8 dots with center point 2x2 dots, standard density, 8 dots / column
Hex: 1B 2A 00 08 00 FF 81 81 99 99 81 81 FF
Alternative
$$
$$/
dots per
max. of
column
columns
8
816
8
1632
8
1632
8
3264
8
1088
8
979
8
1224
8
1958
24
816
24
1632
24
1224
24
2448
24
4896
Function
Control String Introducer (CSI) for" ESC [
HEX 1B 5B
Control String Introducer (ESC) for "ESC"
HEX 1B
Select Various Graphics Modes
P2 + P3 * 256 = number of columns
(P2,P3 = 0/0...F/F) v1 .. vn = binary data in
hex code
hor. density
ert. density
( dpi )
no v AGM
60
120
72
120
72
240
72
80
72
72
72
90
72
144
72
60
180
120
180
90
180
180
180
360
180
vert. density
AGM
72
60
60
60
*)
60
*)
60
60
*)
180
180
180
180
180
*)
Appendix D-10