Dew point temperature measurement
Measuring area °C
0 to +50 °C
Measuring range °F
+32 to +122 °F
Relative humidity measurement
Measuring range %RF
0 - 40%RF
40 - 60%RF
60 - 80%RF
80 - 100%RF

b) Degree of emission of different surfaces

The emission degrees listed in the table are approximates. Various parameters, such as geometry and surface qual-
ity, may influence the emission degree of an object.
The meter is delivered with a pre-set emission degree of 0.95. It matches for most non-metal materials. The IR
measuring method is only conditionally suitable for blank metals and requires a special surface treatment (e.g. matte
insulation tape, etc.) or pre-setting of the corresponding degree of emission.
Surface
Aluminium, blank
Aluminium, oxidised
Asphalt
Concrete
Ice
Iron oxide
Colour
Plaster
Glass/porcelain
Rubber, black
Wood
Plastic
Accuracy
±1 °C
±1.5 °C
Accuracy
±1.8 °F
±3 °F
Accuracy
±5%RF
±4%RF
±5%RF
±6%RF
Emission Degree
0.04
0.30
0.90 - 0.98
0.94
0.96 - 0.98
0.78 - 0.82
0.93
0.80 - 0.90
0.92 - 0.94
0.94
0.87 - 0.94
0.90
+10 to +40 °C
Residual range
+50 to +104 °F
Residual range
Surface
Emission Degree
Copper, oxidised
0.60
Brass, oxidised
0.50
Paints, matte
0.93 - 0.97
Foods
0.93 - 0.98
Human skin
0.98
Plastic
0.94
Paper
0.97
Sand
0.90
Textiles
0.90
Water
0.92 - 0.96
Brick, plaster
0.93 - 0.96
Cement
0.94
53