a) Measuring tolerances

The accuracy is valid for one year at a temperature of +23 to +25 °C (+73 to +77 °F), and at a relative humidity of
less than 75%, non-condensing.
Infrared temperature measuring area
Measuring area °C
-50 to +20 °C
+20 to +500 °C
+500 to +1000 °C
+1000 to +1600 °C
Measuring range °F
-58 to +68 °F
+68 to +932 °F
+932 to +1832 °F
+1832 to +2912 °F
Contact temperature measurement type K
Measuring area °C
-50 to 0 °C
0 to +1370 °C
Measuring range °F
-58 to +32 °F
+32 to +2498 °F
Air temperature measurement
Measuring area °C
0 to +50 °C
Measuring range °F
+32 to +122 °F
52
Accuracy
±5 °C
±(1.5% +1.5 °C)
±2%
±2.8%
Accuracy
±9 °F
±(1.5% + 3 °F)
±2%
±2.8%
Accuracy
±3.5 °C
±(1.0% + 2 °C)
Accuracy
±7 °F
±(1.0% + 4 °F)
Accuracy
±1 °C
±1.5 °C
Accuracy
±1.8 °F
±3 °F
Reproducibility
±2 °C
±1% or
±1 °C
±1% or
±1 °C
±1.5%
Reproducibility
±4 °F
±1% or
±1.8 °F
±1% or
±1.8 °F
±1.5%
+10 to +40 °C
Residual range
+50 to +104 °F
Residual range