19. TECHNICAL DATA

a) Base station
Batteries ............................................ 2 x 1.5 V, type AA (alcaline suggested)
Temperature display range ................ -50 °C to +120 °C (-58 °F to +248 °F)
Resolution .......................................... 0.1 °C/°F
Ambient conditions ............................ 0 to +50 ºC, 15 – 85 % RH
Dimensions (W x H x D) .................... 91 x 96 x 28.5 mm
Weight (without batteries) .................. 110 g
b) Remote sensor
Batteries ............................................ 2 x 1.5 V, Typ AAA (alcaline suggested)
Temperature display range
................ -50 °C to +120 °C (-58 °F to +248 °F)
Resolution .......................................... 0.1 °C/°F
Transmission frequency..................... 433 MHz
Accuracy ............................................ +/- 2 °C
Measuring rate ................................... approx. every 10 seconds
Transmission rate .............................. approx. every 50 seconds
Transmission distance ....................... up to 40 m in free sight
Ambient conditions ............................ 0 to +50 ºC, 15 – 85 % RH
Dimensions (W x H x D) .................... 56.5 x 90 x 24 mm
Weight (without batteries) .................. 45 g
c) Type K temperature sensor
Temperature range ............................ -50 °C to +120 °C

20. DECLARATION OF CONFORMITY (DOC)

We, Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that this
product complies with the fundamental requirements and the other relevant regulations of the
directive 1999/5/EC.
The declaration of conformity for this product is available at www.conrad.com