Herunterladen Inhalt Inhalt Diese Seite drucken

Degree Of Emission Of Different Surfaces - VOLTCRAFT IR-1600 CAM Bedienungsanleitung

Infrarot-thermometer
Vorschau ausblenden Andere Handbücher für IR-1600 CAM:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Dew point temperature measurement
4
Measuring area °C
0 to +50 °C
Measuring range °F
+32 to +122 °F
Relative humidity measurement
5
Measuring range %RH
0 - 40 %RH
40 - 60 %RH
60 - 80 %RH
80 - 100 %RH
b) Degree of emission of different surfaces
The emission degrees listed in the table are approximates. Various parameters, such as geometry and surface quality,
may influence the emission degree of an object.
The meter is delivered with a pre-set emission degree of 0.95. It matches for most non-metal materials. The IR
measuring method is only conditionally suitable for blank metals and requires a special surface treatment (e.g. matte
insulation tape, etc.) or pre-setting of the corresponding degree of emission.
Surface
Aluminium, blank
Aluminium, oxidised
Asphalt
Concrete
Ice
Iron oxide
Colour
Plaster
Glass/porcelain
Rubber, black
Wood
Plastic
Accuracy
±1 °C
±1.5 °C
Accuracy
±1.8 °F
±3 °F
Accuracy
±5 %RH
±4 %RH
±5 %RH
±6 %RH
Emission Degree
0.04
0.30
0.90 - 0.98
0.94
0.96 - 0.98
0.78 - 0.82
0.93
0.80 - 0.90
0.92 - 0.94
0.94
0.87 - 0.94
0.90
+10 to +40 °C
Residual range
+50 to +104 °F
Residual range
Surface
Copper, oxidised
Brass, oxidised
Paints, matte
Foods
Human skin
Plastic
Paper
Sand
Textiles
Water
Brick, plaster
Cement
Emission Degree
0.60
0.50
0.93 - 0.97
0.93 - 0.98
0.98
0.94
0.97
0.90
0.90
0.92 - 0.96
0.93 - 0.96
0.94
51

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

1274960

Inhaltsverzeichnis