• "RCL" to fetch data from the measured-data memory at any time as long as the
DMM ist not turned off yet,
• an automatic switch-off function (Auto Current Off) turns the DMM off after abt. 30
minutes of non-use to avoid burdening the batteries in an unnecessary way, and
• an integrated USB interface (Universal Serial Bus) for data transfer by means of a
PC.
The measuring instrument can be universally employed in both the hobby and indu-
strial fields (under certain conditions, CAT II) or even at schools.
An alkaline 9 V block battery, e.g. the 6LR61 or MN1604 or 6F22 or 006P types as
are necessary is used for current suppy.
Setting elements
(For an illustration, see the fold-out page)
Multimeter
(1) USB interface (B type) under the housing lid.
(1a) Multi-function LCD display (LCD = liquid crystal display).
(2) "Current" switch to turn on and off.
(3) "Range" push-button to manually select the measuring range, deactivates the
AUTO-Range; sub-function of MIN/MAX memory display.
(4) "REL" push-button to measure differences; sub-function of reading out (RCL =
Recall = fetch back) the integrated memory locations.
(5) "BLUE" key to initiate the sub-functions.
(6) "HOLD" key to "retain" the instantaneous value measured in the left-hand sub-
display. Sub-function: Occupy the "MEM" memory locations.
(7) "DC/AC" key to switch over the direct and alternating magnitudes in the voltage
and current field and to change from the resistance test to the continuity test.
(8) Range selector switch for all measuring ranges.
(9) Connecting socket for capacitance measurement, "S/O"- (Signal output) signal
generator and temperature measurement.
(10) Connecting socket for "hFE" transistor test.
(11) Connecting socket "20A" (current connection for the 20 A measuring range; for
D.C. = "+").
(12) Connecting socket "mA" (current connection for the 400µA and 400 mA measu-
ring ranges; for DC = "+").
(13) Connecting socket "V/Ω" (= "+").
(14) Connecting socket "COM" (Common = Mass = "-").
32
Tolérances de mesure
Indication de la précision en ±(% de la lecture (lecture = rdg) + nombre de chiffres en
digits (= dgt = nombre des décimales les plus petites).
Précision pendant 1 an pour une température de +23 °C ± 5° et une humidité relati-
ve de l'air inférieure à 75 %, non condensant.
Fonction
Plage
Résolution
400 mV
0,1 mV
4 V
1 mV
DC V
40 V
10 mV
400 V
100 mV
1000 V
1V
4 V
1 mV
AC V
40 V
10 mV
(40 Hz à
400 V
100 mV
500 Hz)
750 V
1 V
400 µA
0,2 µA
µA
4 mA
2 µA
DC A
40 mA
20 µA
mA
400 mA
200 µA
20A
20 A
2 mA
400 µA
0,2 µA
µA
AC A
4 mA
2 µA
(40 Hz à
40 mA
20 µA
mA
500 Hz)
400 mA
200 µA
20A
20 A
2 mA
400 Ω
0,1 Ω
1 Ω
4 kΩ
10 Ω
40 kΩ
Ohm
100 Ω
400 kΩ
4 MΩ
1 kΩ
40 MΩ
10 kΩ
Précision
Résistance d'entrée/
protection de surcharge
± (0,5% + 2dgt)
± (0,8% + 2dgt)
10 Mohm
± (1,0% + 3dgt)
± (1,5% + 3dgt)
± (0,8% + 2dgt)
800 mA rapide
± (1,2% + 2dgt)
250 Vrms
± (2,0% + 3 dgt)
15 A rapide /250V GBB
± (1,0% + 5dgt)
800 mA Flink
250 Vrms
± (1,5% + 5dgt)
± (3,0% + 4 dgt)
15 A Flink /250V GBB
± (0,8% + 4dgt)
± (0,8% + 2dgt)
250 Vrms
± (1,0% + 4dgt)
± (1,5% + 5dgt)
81