Herunterladen Inhalt Inhalt Diese Seite drucken

KEB COMBIVERT F5 - Serie Betriebsanleitung Seite 70

Vorschau ausblenden Andere Handbücher für COMBIVERT F5 - Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Display Plaintext COMBIVIS
A. OL
ABN.STOP overload
A.OL2
ABN.STOP overload 2
GB
A.PrF
ABN.STOP prot. rot. for.
A.Prr
ABN.STOP prot. rot. rev.
GB
A.SbuS ABN.Bus synchron
A.SEt
ABN.STOP set
A.SLF
ABN.Software limit
switch forward
A.SLr
ABN.Software limit
switch reverse
GB- 34
Value
Meaning
99
A level between 0 and 100 % of the load counter can be adjusted,
when it is exceeded this warning is output. The response to this
warning can be programmed (see chapter 6.7 "Response to errors or
warning messages").
100
The warning is output when the standstill continuous current is
exceeded (see technical data and overload characteristics). The
response to this warning can be programmed (see chapter 6.7
"Response to errors and warning messages"). The warning message
can only be reset after the cooling time has elapsed and A.nOL2 is
displayed.
94
The drive is driven onto the right limit switch. The response to this
warning can be programmed (see chapter 6.7 "Response to errors
and warning messages").
95
The drive is driven onto the left limit switch. The response to this
warning can be programmed (see chapter 6.7 "Response to errors
and warning messages").
103
Synchronization over sercos-bus not possible. The response to this
warning can be programmed (see chapter 6.7 "Response to errors
and warning messages").
102
Warning: set selection: It has been attempted to select a locked
parameter set. The response to this warning can be programmed (see
chapter 6.7 "Response to errors or warning messages").
104
The right software limit switch lies outside the defined limits. The
response to this warning can be programmed (see chapter 6.7
"Response to errors or warning messages").
105
The left software limit switch lies outside the defined limits. The
response to this warning can be programmed (see chapter 6.7
"Response to errors or warning messages").