Torque reference / Source
Torque reference /
Absolute
With this parameter the required setpoint source for torque control can
be adjusted.
Value Meaning
0
AN1+ / AN1-
1
AN2+ / AN2-
2
digital absolute
3-5
only application mode
Adjustment range:
Resolution:
Factory setting:
Note:
The absolute torque reference of the drive is adjusted with parameter
CP.29 in torque-controlled operation (CP.10 = 5) and with digital setpoint
setting (CP.28 = 2). The sign stands for direction of rotation to be active.
In speed-controlled operation (CP.10 = 4) the parameter works as
torque limit in all quadrants.The sign has no effect at that.
The factory setting depends on the unit size.
Adjustment range:
Resolution:
Factory setting:
Operation of the Unit
0%...±100% = 0...±CP.29
0%...±100% = 0...±CP.29
0...5
1
2
Enter-Parameter
-10000,00...10000,00 Nm
0,01 Nm
CP.29