Herunterladen Inhalt Inhalt Diese Seite drucken

Controller Mode; Slave Mode Without Control Unit; Slave Mode With Control Unit - Metz MECABLITZ 76 MZ-5 digital Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Please note that the slave flash units mecablitz 28 CS-2 digital, 34
CS-..., 44 MZ-2, 45 CL-4 digital only support the remote channel 1
(Co 1)!

17.1 Controller mode

• Switch the camera to the manual mode M.
• Set a shutter speed of 1/60 sec. or slower.
• Select a suitable aperture on the camera.
• Fit the flash unit with an SCA adapter or standard foot 301.
• Set the flash mode TTL (for Metz TTL remote) or auto A (for Metz automatic
remote) on the controller flash unit (see 6)
To operate as controller in the cordless Metz TTL remote mode, the
camera and SCA adapter must support the standard TTL flash mode!
• Press the button "Sel" repeatedly until "Select" appears in the display.
• Select "Remote" with the Up / Down buttons
ted with a bar.
• Press the button "Set" and so confirm the menu selection.
• Select the remote address "Co" (controller) with the Up / Down buttons
. Here, the settings Co1 (remote address 1), Co2 (remote address 2)
and OFF (remote mode off) are possible. The setting takes effect immedia-
tely.
• Press the button "Return"
repeatedly until the normal display is shown.
If the button "Return"
is not pressed, the display automatically switches
back to the normal display after approx. 5 seconds.
"Co" flashes in the field for flash mode in the display and so indicates the
controller mode.
• Wait for the flash readiness of the controller and slaves.
• Trigger a test flash: press the manual firing button
programme the slaves to the remote address set on the controller.
• The slave flash unit responds with a delayed flash and in this way indicates
that it has been programmed and is operational. If several slaves are ope-
rated simultaneously, all the slaves will acknowledge flash readiness simul-
taneously.
If a slave does not respond by firing a delayed flash, then this means that the
sensor
ler. Turn the slave flash unit so that the sensor
the controller. Then retrigger a test flash on the controller.

17.2 Slave mode without control unit

• Switch off the flash unit with the main switch
• Remove the control unit. To remove the control unit's cable, press the
unlocking catch (Fig. 1) on the mount holder against the cable's plug while
pulling out the cable.
• Set up the slave flash unit at the position planned and switch it on. When
operating the handle mount without control unit the slave flash mode is
activated automatically.
. Remote is then highligh-
• Wait until the flash readiness indicator
• Trigger a test flash on the controller (see 17.1).
After being programmed successfully, the slave fires a delayed flash and
the flash readiness indicator flashes (see 17.1.4).
Position 0 = 28 mm;
Position 1/2 = 50 mm;

17.3 Slave mode with control unit

• Switch off the flash unit with the main switch
• Fit the control unit with slave adapter SCA 3083 digital (optional extras).
Select "Metz REMOTE" with the mode switch on the slave adapter.
and in this way
in the slave flash unit did not receive the light pulse of the control-
The zoom position of the main reflector can be set with the switch
in four steps:
Position 1/4 = 35 mm;
Position 1 = 85 mm.
The mode switch of the slave adapter is on the reverse side – behind a
cover which can be opened.
can receive the light pulse of
.
lights up.
.
89

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis