Iec60870-5-101 Master-Parameter; Master Parameter Für S7-300, S7-400 Und Et200S - Siemens SIPLUS RIC IEC on S7 Handbuch

Inhaltsverzeichnis

Werbung

3.3.1. IEC60870-5-101 Master-Parameter

3.3.1.1. Master Parameter für S7-300, S7-400 und ET200S
FB100
Registration_Code
Line_ID
L1_Local_ID
*1)
L1_Laddr_HW
*2)
L1_Data_Wait_Time *3)
L1_Time_RTS_OFF *3)
L2_Length_Link_Address
L2_Link_Address
L2_TimeOut_SendConfirm
L2_Time_Pollcycle
L2_TimeOut_RcvInfo
L2_Repeats_on_Timeout
L2_Balanced_mode
L2_Dir_Bit
L2_E5_as_ACK_NACK
L2_UnbalMaster_noCL2Poll
L7_Length_ASDU_Address
L7_Length_Info_Addresses
L7_With_Originator
Buffer_Handling
Next_Info
Do_Restart
First_internal_DB_No
Serial_from_CPU
SIPLUS RIC IEC on S7 V1.5
Funktionsbeschreibung
Typ
Default
IN
DWORD
DW#16#0
IN
INT
1
IN
WORD
W#16#1000
IN
INT
0
IN
TIME
T#10ms
IN
TIME
T#10ms
IN
INT
1
IN
DINT
L#1
IN
TIME
T#2S
IN
TIME
T#500ms
IN
TIME
T#30S
IN
INT
2
IN
BOOL
FALSE
IN
BOOL
TRUE
IN
BOOL
TRUE
IN
BOOL
FALSE
IN
INT
1
IN
INT
2
IN
BOOL
FALSE
IN
BYTE
B#16#0
IN
BOOL
FALSE
IN
BOOL
FALSE
IN
INT
50
IN
BOOL
FALSE
Seite 21 von 235
Baustein-Kommentar / Kurzbeschreibung
!!! IMPORTANT !!! See product information
For differentiation of more than one line;1-x (see ma-
nual); Default: 1;
see NetPro Connection Property 'ID' of your PtP-
Connection
see Address of CP-Module in your HW-Configuration
Time to wait for partner to set CTS on after setting
RTS (Def: T#10ms)
Time to elapse after transmission before RTS turns off
(Def: T#10ms)
Length of Link-Address (0,1,2 Octets); Default: 1
Link-Address: 1-254, 1-65534; Default: 1
Timeout for answers; Default: 2 sec (T#2s)
only unbal.mode master: time between two polls, if no
ACD is in answer(T#500ms)
unbal.Slave -> Cycle Error, bal mode -> Linktest, 0 ->
not active, Default 30s
No of Repeats on Timeout; Default: 2
0 -> unbalanced mode (slave) 1-> balanced mode;
Default: 0
balanced mode: 1=Set DIR-Bit in Send-Telegrams;
Default: 1
1 -> E5 will be accepted as ACK (FC0) and NACK
(FC9); Default: 1
only unbalanced master: Polling only with Class1-
Request, no Class2-Requests
Length of ASDU-Address (1 or 2 Octets); Default: 1
Length of Infoobject-Addresses (1, 2 or 3 Octets);
Default: 2
0 -> without Originator; 1 -> with Originator; Default: 0
0(def): compl, 1:compl. if ov 2:oldest Info will deleted;
3:no act.
Only allowed for additional calls in a Cycle ->reduced
operation -> next info
a rising edge restarts the IEC-Application
First DB-Number for DBs created by the Runtime
Software; Default: 50;
For Registration use serial number from CPU instead
of memory card
I IA CE
©SIEMENS AG 2013