Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Fuse - TOOLCRAFT ST-100HF Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ST-100HF:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

13. Replacing the fuse

The fuse protects the device against overload. The fuse should not be triggered during normal use.
The fuse may be triggered by a fault in the soldering iron or a short circuit in the cable between the soldering iron and
the soldering station. The fuse may also be triggered by a fault in the soldering station.
Follow the steps below to replace a defective fuse:
• Switch off the soldering station. If the soldering iron is still hot, allow it to cool down completely.
• Disconnect the soldering station from the mains voltage (remove the plug from the mains socket). Then disconnect
the mains cable from the soldering station.
• Remove the fuse holder (5) below the power-in socket (6). This can be carefully prised out of place with a flat
screwdriver.
• Remove the fuse from the fuse holder.
• Check the fuse, e.g. with an appropriate meter (digital multimeter).
If the fuse is defective, replace it with a new fuse of the same type (see "Technical data" at the end of these operat-
ing instructions).
Never use a fuse with other specifications. Never bridge a defective fuse!
This constitutes a fire hazard!
• Insert the new fuse into the fuse holder. Insert the fuse holder back into the soldering station until it clicks into place.
• Connect the soldering station to the mains and switch it back on.
If the fuse blows again, disconnect the soldering station from the mains and ask a technician to conduct a
comprehensive check.