Technical data

Information / pump type
Weight
Power P1 / P2
Speed
Operating voltage
Nominal current (per pump)
Max. pumping capacity
Max. pumping height
Max. temperature
Pumped medium
Protection rating
Protection class
Operating mode
Motor protection
Recommended fuse
(Mono)
Recommended fuse (Duo)
Residual current device (RCD)
Pumping capacity and height of the pumps
Tank
Data
Weight
Inlet [DN]
Pressure connection [DN]
Cable conduit
Ventilation
Height
Outside diameter
Cover plate / version
Pumping volume
016-233_01
GTF 600
6 kg
650W / 400 W
2750 rpm
230 V; 50 Hz
2.9 A
12 m³/h
8 m
35°C
IP68 (3m)
I
S1
integrated
C16 A
C16 A
30 mA
Values
16 kg
100 / 150
must be drilled on-site
50 (d=63 mm) for PVC
must be drilled on-site
must be drilled on-site
must be drilled on-site
830 mm
600 mm
walkonable up to 300 kg
60 l
GTF 1250
10 kg
1.3 kW / 0.8 kW
2700 rpm
230 V; 50 Hz
5.4 A
20 m³/h
10 m
35°C
IP68 (3m)
I
S3 (50%)
integrated
C16 A
C16 A
30 mA
25 / 116