7. Adapting run

After the batteries have been inserted, the motor first travels
back, during which the date, „INS" and the activity sym-
bol
are displayed. As soon as „INS" without the activity
symbol
is displayed, the programmable radiator control
unit can be installed. An adapting run („AdA") is performed
after installation to adapt to the valve.
• Place the programmable radiator control unit on the val-
ve.
• Tighten the union nut firmly.
• Press the OK key , when „INS" is shown in the display.
The actuator carries out an adapting run. During this time
„AdA" and the activity symbol
and operation is not possible.
If the adapting run is initiated before installation, press
OK and the motor travels back to the „INS" position.
If an error message (F1, F2, F3) is displayed, the motor
similarly travels back to the „INS" position.

8. Setting the weekly program

Up to 3 heating phases (7 switching time points) can be set
separately for each weekday in the weekly program. The
programming is done for the selected days and tempera-
tures must be stored for a time period from 00:00 to 23:59.
• Press the Menu key longer than 3 seconds. „PRO" ap-
pears in the display. Confirm with the OK key.
• „DAY" appears in the display. With the selector dial can
be selected an individual weekday, all working days, the
weekend or the whole week (example working days).
40
40
are shown in the display
• Confirm with the OK key.
• The first switching time point is dis-
played (0:00), this can not be chan-
ged. The heating times are also dis-
played as bars.
• Confirm with the OK key.
• After this you can set the temperature which is desired
from 0:00 (example 17.0 °C).
• Confirm with the OK key.
• The next switching time point is dis-
played (example 6:00). You can ad-
just this individually.
• Finally set the temperature which
should prevail from 6:00.
• You can repeat this procedure un-
til all the other desired temperatu-
res for the time period from 0:00 to
23:59 have been stored.
• If all 7 switching time points have
been allocated, 23:59 is displayed
as the final switching point to be
confirmed.
The temperature can also be changed in Auto Mode at any
time via the selector dial.The changed temperature is then
retaineduntil the next switching time point.

8.1. Weekly program: examples

Up to 3 heating times (7 switching time points) with individual
temperature setting can be stored for each weekday with the
programmable radiator control unit.