After the batteries have been inserted, the motor first travels
back, during which the date, „INS" and the activity sym-
bol
are displayed. As soon as „INS" without the activity
symbol
is displayed, the programmable radiator control
unit can be installed. An adapting run („AdA") is performed
after installation to adapt to the valve.
• Place the programmable radiator control unit on the val-
ve.
• Tighten the union nut firmly.
• Press the OK key , when „INS" is shown in the display.
The actuator carries out an adapting run. During this time
„AdA" and the activity symbol
and operation is not possible.
If the adapting run is initiated before installation, press
OK and the motor travels back to the „INS" position.
If an error message (F1, F2, F3) is displayed, the motor
similarly travels back to the „INS" position.
Up to 3 heating phases (7 switching time points) can be set
separately for each weekday in the weekly program. The
programming is done for the selected days and tempera-
tures must be stored for a time period from 00:00 to 23:59.
• Press the Menu key longer than 3 seconds. „PRO" ap-
pears in the display. Confirm with the OK key.
• „DAY" appears in the display. With the selector dial can
be selected an individual weekday, all working days, the
weekend or the whole week (example working days).
40
40

7. Adapting run

8. Setting the weekly program

are shown in the display