Motor mounting

Motor connection

{
Danger!
After the connection of a PTC thermistor or thermal contact
l
all control terminals only have a basic insulation (single
insulating distance).
Protection against contact in the event of a defective
l
insulating distance can only be ensured by external measures
(e.g. double insulation).
(
Stop!
Terminal X2 and sheet must not be disconnected!
!
5.5 mm
X2
8200mot055
X2/T1,
Connection terminals for motor temperature monitoring with PTC thermistor or thermostat
X2/T2
(NC contact).
Activate the motor temperature monitoring under C0119 (e. g. C0119 = 1)!
90
efesotomasyon.com - Lenze
5.5 mm
3.4 Nm
PE
30 lb-in
Fig. 19
X2
1a
EDK82MV371 DE/EN/FR 6.0
0.5...0.6 Nm
4.4...5.3 lb-in
2
2.5 mm
AWG 12
6mm
X2
U
W V
PE T2 T1
T2
T1
ϑ >
W2
U2
V2
U1 V1 W1 PE