Relay output connection

1a
Function
X1/K11
NC contact relay output
X1/K12
Relay middle contact
X1/K14
NO contact relay output
PES
HF screen termination by PE connection with a surface as large as possible
)
Note!
For switching the control signals use shielded cables and
l
establish an HF shield termination by PE connection.
For mains potential switching unshielded cables are
l
sufficient.
With inductive or capacitive loads a corresponding protective
l
circuit is required in order to protect the relay contacts!
The service life of the relay depends on the type of load
l
(ohmic, inductive or capacitive) and the value of the switching
capacity.
The output message can be changed under C0008 or
l
C0415/1.