8
Fault detection and elimination
Faulty drive behaviour
Fault
Motor parameter identification
stops with error LP1
Unacceptable drive response
with vector control
Torque dip in the field weakening
range
Stalling of the motor when
operating in the field weakening
range
122
efesotomasyon.com - Lenze
Cause
Motor too small compared with rated power
DC brake active via terminal
various
various
EDK82MV371 DE/EN/FR 6.0
Remedy
Vector control
optimisation
(^ 108)
Contact Lenze
L