11 Store
Enables to store in eeprom the values of peak, totalizer, sum function and tare
zero. If disabled, at starting the above-mentioned values start from 0. The
storing is done automatically every 5 minutes.
Disabled (Default)
Enabled
12 Filter samples
ADC Filter: number of input sensor readings to calculate the mean that defines
process value. NB: when readings increase, control loop speed slows down.
1 to 15 means Default: 10.
13 Sampling frequency
Sampling frequency of analogue / digital converter.
NB: Increasing the conversion speed will slow down reading stability (ex: for
fast transients, as pressure, it is advisable to increase sampling frequency)
242 Hz
123 Hz
62 Hz
50 Hz
39 Hz
33.2 Hz
19.6 Hz
16.7 Hz (Default) 59.9ms Ideal for filtering noises 50 / 60 Hz
12.5 Hz
10 Hz
8.33 Hz
6.25 Hz
4.17 Hz
4.2ms (Maximum speed conversion)
8.2ms
16.1ms
20ms
25.6ms
30.1ms
51ms
80ms
100ms
120ms
160ms
240ms (Minimum speed conversion)
User manual - UA964801